search
for
 About Bioline  All Journals  Testimonials  Membership  News


Biotecnologia Aplicada
Elfos Scientiae
ISSN: 0684-4551
Vol. 17, No. 2, 2000, pp. 102-104
Bioline Code: ba00024
Full paper language: Spanish
Document type: Research Article
Document available free of charge

Biotecnologia Aplicada, Vol. 17, No. 2, 2000, pp. 102-104

 es Estudio Comparativo de dos Sistemas de Captura de la Proteína de 24 kD del Virus de Inmunodeficiencia Humana Tipo 1
Izquierdo, Maricela; Silva, Eladio; Díaz, Héctor; Lubián, Ana L.; Nibot, Carmen & Tabares, Dolores

Resumen

Se realizó un estudio comparativo entre los sistemas HIV-1 P24 Antigen ELISA Test (Coulter, EUA) y DAVIH-Ag P24 (Laboratorios DAVIH, Cuba) para la detección del antígeno P24 del VIH-1. Mediante ambos sistemas se estudiaron en paralelo 1 039 muestras de suero de donantes de sangre y 323 de individuos seropositivos en diferentes estadios de infección por VIH-1. La presencia de antígeno se relacionó con el grupo clínico y los niveles de anticuerpos contra la P24. Los resultados mostraron que ambos diagnosticadores son altamente específicos (más de 99%), con una concordancia de 99,7%. Para la población positiva estudiada, el sistema DAVIH-Ag P24 resultó más sensible que el sistema de la firma Coulter. Los por cientos de antigenemia fueron mayores en el grupo de los pacientes de SIDA. Los títulos de anticuerpos contra la P24 resultaron ser bajos o no reactivos en todos los sueros con antigenemia a esta proteína. Se concluyó que el sistema DAVIH-Ag P24 puede ser utilizado para el seguimiento de personas infectadas con el VIH-1 como marcador pronóstico de la infección, y para el pesquisaje de la P24 en los bancos de sangre.

Palabras-clave
antigenemia, ELISA, marcadores de progresión, P24, seroconversión, VIH-1

 
 en Comparative Study of Two Capture Systems for the 24-kD protein of Human Immunodeficiency Virus
Izquierdo, Maricela; Silva, Eladio; Díaz, Héctor; Lubián, Ana L.; Nibot, Carmen & Tabares, Dolores

Abstract

A comparative study between HIV-1 Antigen ELISA Test (Coulter, USA) and DAVIH-Ag P24 (DAVIH Laboratories, Cuba) was performed for the detection of HIV-1 P24 antigen. A total of 1039 serum samples of blood donors. sera were studied, in addition to 323 sera from seropositive individuals in different stages of the disease. The presence of antigen was associated with the clinical group and the levels of antibodies against P24. Both systems showed a high specificity (greater than 99%) with a concordance of 99.7%. DAVIH-Ag P24 system showed a sensitivity (58/31) greater than Coulter system when it was tested in the positive population. Percents of antigenemia were greater in the AIDS group. Antibody titers against P24 were low or absent in all the sera with antigenemia to this protein. It was concluded that DAVIH-Ag P24 system can be used in the follow-up of HIV-1 infected individuals as a progression marker of the infection, and to screen P24 in blood banks.

Keywords
antigenemia, ELISA, HIV-1, P24, progression markers, seroconversion

 
© Copyright 2000 Elfos Scientiae
Alternative site location: http://elfosscientiae.cigb.edu.cu/Archivo.asp?Id=6

Home Faq Resources Email Bioline
© Bioline International, 1989 - 2024, Site last up-dated on 01-Sep-2022.
Site created and maintained by the Reference Center on Environmental Information, CRIA, Brazil
System hosted by the Google Cloud Platform, GCP, Brazil