search
for
 About Bioline  All Journals  Testimonials  Membership  News


Indian Journal of Human Genetics
Medknow Publications on behalf of Indian Society of Human Genetics
ISSN: 0971-6866
EISSN: 0971-6866
Vol. 17, No. 1, 2011, pp. 17-21
Bioline Code: hg11005
Full paper language: English
Document type: Research Article
Document available free of charge

Indian Journal of Human Genetics, Vol. 17, No. 1, 2011, pp. 17-21

 en A latest and promising approach for prediction of viral load in hepatitis B virus infected patients
Yalamanchili, Naresh; Syed, Rahamathullah; Chandra, Madhavi; Satti, Vishnupriya; Rao, Ramachandra; Mohammed, Aejaz Habeeb & Nanne, Khaja Mohammed

Abstract

Introduction: Designing a rapid, reliable and sensitive assay for detection of hepatitis B virus (HBV) variants by real-time PCR is challenging at best. A recent approach for quantifying the viral load using a sensitive fluorescent principle was brushed in this study.
Materials and Methods : A total of 250 samples were collected from the outpatient unit, CLRD. Complete Human HBVDNA sequences (n = 944) were selected from the National Centre for Biotechnology Information (NCBI), primers and probes were designed and synthesized from the core, surface, and x region. Real-time based quantification was carried out using a standard kit and in-house generated standards and RT-PCR protocols.
Results and Discussion: The standard calibration curve was generated by using serial dilution 10 2 to 10 8 . The calibration curve was linear in a range from 10 2 to 10 8 copies/ml, with an R2 value of 0.999. Reproducibility as measured by dual testing of triplicates of serum samples was acceptable, with coefficients of variation at 6.5%, 7.5%, and 10.5%. Our results showed that amplification performance was good in the case of the x-region-based design (98%). Out of 100 negative samples screened by enzyme linked immunosorbent assay and the standard RT-PCR kit, one sample was detected as positive with the in-house developed RT-PCR assay, the positivity of the sample was confirmed by sequencing the amplified product, NCBI accession EU684022.
Conclusion: This assay is reproducible showing limited inter- and intra-assay variability. We demonstrate that the results of our assay correlated well with the standard kit for the HBV viral load monitor.

Keywords
Hepatitis B virus, quantification, real-time Polymerase Chain Reaction, TaqMan chemistry 19p 13.3, genetic markers

 
© Copyright 2011 Indian Journal of Human Genetics.
Alternative site location: http://www.ijhg.com/

Home Faq Resources Email Bioline
© Bioline International, 1989 - 2024, Site last up-dated on 01-Sep-2022.
Site created and maintained by the Reference Center on Environmental Information, CRIA, Brazil
System hosted by the Google Cloud Platform, GCP, Brazil