search
for
 About Bioline  All Journals  Testimonials  Membership  News


Journal of Indian Association of Pediatric Surgeons
Medknow Publications on behalf of the Indian Association of Pediatric Surgeons
ISSN: 0971-9261
EISSN: 0971-9261
Vol. 12, No. 2, 2007, pp. 65-67
Bioline Code: ip07024
Full paper language: English
Document type: Research Article
Document available free of charge

Journal of Indian Association of Pediatric Surgeons, Vol. 12, No. 2, 2007, pp. 65-67

 en Evaluation of the vascularity of an isolated bowel segment using fluorescein angiography in rats
Chandrasekharam, V.V.S.S; Talwar, D & Bhatnagar, V

Abstract

Aims: An isolated bowel segment (IBS), a viable loop of bowel completely free of its mesenteric attachments, has potential clinical use in bowel lengthening and other techniques. The end point of successful creation of an IBS is the development of adequate collateral circulation. In this experimental study, we report the use of fluorescein test to demonstrate collateral vascularity of the IBS in rats. A simple technique for the visualization and photography of fluorescein in the tissues is also described.
Materials and Methods: In nine Wistar rats, 5 cm of distal ileum was anastomosed side-to-side to 5 cm of proximal colon using 6/0 PDS. In one rat (control), the colon patch was isolated from the rest of the large bowel immediately and fluorescein test was performed. The remaining eight (study group) rats were operated after 8 weeks and the procedure followed as in the control rat. In the last rat, the mesentery of the colon patch was severed; and 2 weeks later, the fluorescein test was performed.
Results: The colon patch in the control rat showed complete lack of fluorescence; in the seven rats tested after 8 weeks, patchy fluorescence was demonstrated in the colon patch; and in the last rat, bright fluorescence of the whole patch could be demonstrated within a few seconds following fluorescein injection.
Conclusion: This study describes a simple technique for the fluorescein test. The observation that the vascular collaterals were more abundant after mesocolic division was obviously due to the opening up of collaterals over a period of time. The fluorescein test is a rapid and easy test and can be easily reproduced.

Keywords
Collateral circulation, colon patch, fluorescein test, isolated bowel segment

 
© Copyright 2007 Journal of Indian Association of Pediatric Surgeons.
Alternative site location: http://www.jiaps.com/

Home Faq Resources Email Bioline
© Bioline International, 1989 - 2024, Site last up-dated on 01-Sep-2022.
Site created and maintained by the Reference Center on Environmental Information, CRIA, Brazil
System hosted by the Google Cloud Platform, GCP, Brazil