search
for
 About Bioline  All Journals  Testimonials  Membership  News


Indian Journal of Medical Sciences
Medknow Publications on behalf of Indian Journal of Medical Sciences Trust
ISSN: 0019-5359
EISSN: 0019-5359
Vol. 60, No. 10, 2006, pp. 407-416
Bioline Code: ms06060
Full paper language: English
Document type: Research Article
Document available free of charge

Indian Journal of Medical Sciences, Vol. 60, No. 10, 2006, pp. 407-416

 en Study on the injection practices of health facilities in Jingzhou district, Hubei, China
Yan Youwang; Zhang Guangping; Chen Yu; Zhang Anqiang; Guan Yong & Ao Hongping

Abstract

BACKGROUND: Some studies indicate unsafe injection practices, which are associated with the transmission of blood-borne pathogens, exist extensively, in the developing countries.
AIMS: To investigate the status of injection services, knowledge and attitude of health workers with regard to injection practices at all levels of the health facilities in Jingzhou district of China; and to provide useful scientific data in order to formulate a feasible, standard measure on injection safety.
SETTINGS: Four district health care facilities, 6 township health centers, 14 village clinics and 14 community health stations.
DESIGN : A retrospective cross-sectional study.
MATERIALS AND METHODS: By examining the medical records in 2004, observing injection practices and interviewing health workers, the quantitative and qualitative data were collected and analyzed.
RESULTS: Out of 1,452 medical records sampled, 1,450 patients had received at least one injection in the period of hospitalization, with an injection rate of about 100% and an average of 10.9 injections per patient. The most frequent injected drug was antibiotic (48%, 7,674/15,857). The prescriptions of 5,655 outpatients were detected, with an injection rate of 52% (2,962). The field observation found that the proportion of unsafe injections was 16% (28/175) and that of unnecessary injections was 57% (99/175). Among 118 professional employees interviewed, those who knew that human immunodeficiency virus, hepatitis C virus and hepatitis B virus might be transmitted by the contaminated syringes and needles accounted for 95% (112), 59% (70) and 89% (105) respectively.
CONCLUSIONS: Among the medical facilities of Jingzhou district, the injection rate was very high and the quality of injection practices should be further improved.

Keywords
Health care facility, injection rate, knowledge of safe injections, safe injection

 
© Copyright 2006 Indian Journal of Medical Sciences.
Alternative site location: http://www.indianjmedsci.org/

Home Faq Resources Email Bioline
© Bioline International, 1989 - 2024, Site last up-dated on 01-Sep-2022.
Site created and maintained by the Reference Center on Environmental Information, CRIA, Brazil
System hosted by the Google Cloud Platform, GCP, Brazil