search
for
 About Bioline  All Journals  Testimonials  Membership  News


Neurology India
Medknow Publications on behalf of the Neurological Society of India
ISSN: 0028-3886
EISSN: 0028-3886
Vol. 59, No. 5, 2011, pp. 696-699
Bioline Code: ni11213
Full paper language: English
Document type: Research Article
Document available free of charge

Neurology India, Vol. 59, No. 5, 2011, pp. 696-699

 en 3D volumetry comparison using 3T magnetic resonance imaging between normal and adenoma-containing pituitary glands
Roldan-Valadez, Ernesto; Garcia-Ulloa, Ana Cristina.; Gonzalez-Gutierrez, Omar & Martinez-Lopez, Manuel

Abstract

Background: Computed-assisted three-dimensional data (3D) allows for an accurate evaluation of volumes compared with traditional measurements.
Aims: An in vitro method comparison between geometric volume and 3D volumetry to obtain reference data for pituitary volumes in normal pituitary glands (PGs) and PGs containing adenomas.
Design: Prospective, transverse, analytical study.
Materials and Methods: Forty-eight subjects underwent brain magnetic resonance imaging (MRI) with 3D sequencing for computer-aided volumetry. PG phantom volumes by both methods were compared. Using the best volumetric method, volumes of normal PGs and PGs with adenoma were compared. Statistical analysis used the Bland-Altman method, t-statistics, effect size and linear regression analysis.
Results: Method comparison between 3D volumetry and geometric volume revealed a lower bias and precision for 3D volumetry. A total of 27 patients exhibited normal PGs (mean age, 42.07 ± 16.17 years), although length, height, width, geometric volume and 3D volumetry were greater in women than in men. A total of 21 patients exhibited adenomas (mean age 39.62 ± 10.79 years), and length, height, width, geometric volume and 3D volumetry were greater in men than in women, with significant volumetric differences. Age did not influence pituitary volumes on linear regression analysis.
Conclusions: Results from the present study showed that 3D volumetry was more accurate than the geometric method. In addition, the upper normal limits of PGs overlapped with lower volume limits during early stage microadenomas.

Keywords
3D volumetry, Bland-Altman plot, geometric volume, magnetic resonance imaging, pituitary adenoma, pituitary volume

 
© Copyright 2011 Neurology India.
Alternative site location: http://www.neurologyindia.com

Home Faq Resources Email Bioline
© Bioline International, 1989 - 2024, Site last up-dated on 01-Sep-2022.
Site created and maintained by the Reference Center on Environmental Information, CRIA, Brazil