 en SHORT COMMUNICATION - Direct Sensitivity Test of the MB/BacT System
Angela Maria Werneck Barreto; Joselba Borges Melo Araujo; Reginalda Ferreira de Melo Medeiros & Paulo Cesar de Souza Caldas

Abstract

In order to evaluate the direct-method test of sensitivity to drugs used in the principal tuberculosis treatment regimes, in the Organon Teknika MB/BacT system, we tested 50 sputum samples positive to microscopy taken from patients with pulmonary tuberculosis and with clinical indications for an antibiogram, admitted sequentially for examination during the routine of the reference laboratory. The material was treated v/v with 23% trisodium phosphate solution, incubated for 24 h at 35°C, and neutralized v/v with 20% monosodium phosphate solution. The material was then centrifuged and the sediment inoculated into flasks containing Rifampin - 2 μg/ml, Isoniazid - 0.2 μg/ml, Pyrazinamide - 100 μg/ml, Ethambutol - 2.5 μg/ml, Ethionamide - 1.25 μg/ml, and Streptomycin - 2 μg/ml. The tests were evaluated using the indirect method in the BACTEC 460 TB (Becton Dickinson) system as the gold standard. The results showed that the Rifampin test performed best, i.e., 100% sensitivity at 95% Confidence Interval (82.2-100) and 100% specificity at 95% Confidence Interval (84.5-100), followed by Isoniazid and Pyrazinamide. In this experiment, 92% of the materials showed a final reading in 30 days; this period represents the time for primary isolation as well as the results of the sensitivity profile, and is within Centers for Disease Control and Prevention recommendations regarding time for performance of the antibiogram. The inoculated flasks showed no contamination during the experiment. The MB/BacT is shown to be a reliable, rapid, fully automated nonradiometric system for the tuberculosis antibiogram.

Keywords
tuberculosis - drug resistance- laboratory diagnostics

 
© Copyright 2002 - Instituto Oswaldo Cruz - Fiocruz
Alternative site location: http://memorias.ioc.fiocruz.br

Home Faq Resources Email Bioline
© Bioline International, 1989 - 2024, Site last up-dated on 01-Sep-2022.
Site created and maintained by the Reference Center on Environmental Information, CRIA, Brazil
System hosted by the Google Cloud Platform, GCP, Brazil