search
for
 About Bioline  All Journals  Testimonials  Membership  News


Brazilian Journal of Oral Sciences
Piracicaba Dental School - UNICAMP
EISSN:
Vol. 6, No. 20, 2007, pp. 1283 - 1288
Bioline Code: os07008
Full paper language: English
Document type: Research Article
Document available free of charge

Brazilian Journal of Oral Sciences, Vol. 6, No. 20, 2007, pp. 1283 - 1288

 en Research on staphylococcus spp check for this species in other resources in biofilm formation in water pipes and sensibility to antibiotics
Lancellotti, Marcelo; de Oliveira, Mônica Pereira & de Ávila, Fernando Antonio

Abstract

Water from dental equipment presents risks for surgeon-dentists as well as for patients because it might work as a means of dissemination/transmission of microorganisms. The objective of this study was to verify the quality of the water used in dental equipment by means of microbiological analysis, accomplishing the count of Staphylococcus spp. There have been collected 160 samples of water from reservoirs, taps used for hand washing, air-water syringes, and high-speed handpieces, in 40 dental offices in the city of Barretos, São Paulo. The rules concerning bacteriological analysis in cfu/mL from Standard Methods for the Examination of Water and Wastewater have been followed. The analysis of the results has made it possible to verify that out of the total of samples, 28% did not meet the standards of potability established by the American Dental Association. Regarding the origin of analyzed S. aureus, the most contaminated sites were high-speed handpieces in private offices (76%) and in dental care plan offices (71%), followed by air-water syringe in dental care plan offices (64%). For S. epidermidis samples, the most contaminated sites were high-speed handpieces in SUS (Brazilian Government Health System) dental offices (22%) and in dental care plan offices (14%). The most contaminated sites were dental offices that saw patients under dental care plans. Concerning tested antibiotics, the ones that presented better results as to sensibility to strain S. epidermidis were vancomycin and ciprofloxacin (100%) and, as to sensibility to strain S. aureus, it was ciprofloxacin (97%).

Keywords
Staphylococcus spp, cross contamination, biofilm, dental office, water line

 
© Copyright 2007 - Piracicaba Dental School - UNICAMP São Paulo - Brazil
Alternative site location: http://www.fop.unicamp.br/brjorals

Home Faq Resources Email Bioline
© Bioline International, 1989 - 2024, Site last up-dated on 01-Sep-2022.
Site created and maintained by the Reference Center on Environmental Information, CRIA, Brazil
System hosted by the Google Cloud Platform, GCP, Brazil