Original Article

Algorithm for recall of HIV reactive Indian blood donors by sequential immunoassays enables selective donor referral for counseling

Department of Transfusion Medicine, Postgraduate Institute of Medical Education and Research, Chandigarh
Correspondence Address:Department of Transfusion Medicine, Postgraduate Institute of Medical Education and Research, Chandigarh, neelam2918@yahoo.com

Code Number: jp06034

Abstract

Background: HIV/AIDS pandemic brought into focus the importance of safe blood donor pool.
Aims:
To analyze true seroprevalence of HIV infection in our blood donors and devise an algorithm for donor recall avoiding unnecessary referrals to voluntary counseling and testing centre (VCTC).
Materials and Methods:
39,784 blood units were screened for anti-HIV 1/2 using ELISA immunoassay (IA-1). Samples which were repeat reactive on IA-1 were further tested using two different immunoassays (IA-2 and IA-3) and Western blot (WB). Based on results of these sequential IAs and WB, an algorithm for recall of true HIV seroreactive blood donors is suggested for countries like India where nucleic acid testing or p24 antigen assays are not mandatory and given the limited resources may not be feasible.
Results:
The anti-HIV seroreactivity by repeat IA-1, IA-2, IA-3 and WB were 0.16%, 0.11%, 0.098% and 0.07% respectively. Of the 44 IA-1 reactive samples, 95.2% (20/21) of the seroreactive samples by both IA-2 and IA-3 were also WB positive and 100% (6/6) of the non-reactive samples by these IAs were WB negative. IA signal/cutoff ratio was significantly low in biological false reactive donors. WB indeterminate results were largely due to non-specific reactivity to gag protein (p55).
Conclusions:
HIV seroreactivity by sequential immunoassays (IA-1, IA-2 and IA-3; comparable to WHO Strategy-III) prior to donor recall results in decreased referral to VCTC as compared to single IA (WHO Strategy-I) being followed currently in India. Moreover, this strategy will repose donor confidence in our blood transfusion services and strengthen voluntary blood donation program.

Keywords: Donor Recall, HIV, ELISA, rapid tests, biological false reactive

Introduction

HIV/AIDS pandemic brought into focus the importance of safe blood donor pool. Presently in India WHO Strategy-I is used for screening donors′blood for HIV, according to which serum/plasma is tested only once by E/R/S (ELISA/Rapid/Simple) assay for HIV antibodies. If negative, the unit is considered free of HIV and if reactive the unit is discarded. The dilemma in screening low-risk populations such as blood donors is that a large proportion of primary immunoassay reactive results represents false positive reactions also known as biological false reactive (BFR).[1],[2] Revealing transfusion transmitted disease (TTD) status to blood donors was not permissible earlier in India. From September 2003, according to Objective 4.16 of Indian Action Plan for Blood Safety, the donor is counseled about TTDs prior to donation and is offered the option of knowing his TTD status provided he has given consent for the same.[3] According to this, donors found seroreactive by initial HIV screening assay are directed by blood transfusion services (BTS) to a linked Voluntary Counseling and Testing Centre (VCTC) for counseling and further confirmatory testing without repeating tests in blood banks.

In India, on an average 52% of the donors are voluntary and 48% are replacement donors.[4] None of the licensed blood banks in India collect blood from paid donors as per the Supreme Court ruling in 1996. In India, more than 90% of the donors are males since the prevalence of iron deficiency anemia in females is 35-64%.[5],[6] Unless Indian transfusion practice can approach a totally altruistic donation model with anonymity and education of donors about the test results, stigmatization of HIV positivity without confirmatory tests may lead to unnecessary counseling, personal anxiety and donor deferrals. This can have a negative impact on the voluntary blood donation drive.

This study was conducted to analyze true seroprevalence of HIV infection in our blood donors. On primary HIV 1/2 screen reactive donors′samples, performance of the sequential immunoassays (IA) were compared with that of confirmatory western blot (WB) test. This helped us to devise an algorithm of recall for initial HIV screen reactive blood donors so as to avoid unnecessary referrals to VCTC.

Materials and Methods

A retrospective study was conducted from December 2003 to January 2005, in the Department of Transfusion Medicine of a tertiary care hospital. 39,784 blood units were screened for HIV 1/2 antibodies using 3rd generation indirect ELISA kit (Microlisa HIV 1/2, J Mitra and Co. Ltd, India) (IA-1), besides other mandatory tests (anti-HCV, HBsAg, VDRL and malaria). All kits used were approved by National AIDS Control Organization (NACO), India. As per the WHO Strategy-I, all HIV screen reactive blood units were discarded. The sera of screen reactive units were aliquoted and stored at -20°C for future testing before donor recall. To avoid inter-lot variation; repeat IA-1 was done using the same assay as above but with a different lot number. Samples which were repeat reactive on IA-1 were further tested independently using two sequential IAs based on different principles (IA-2 and IA-3). A 3rd generation sandwich ELISA (Genscreen HIV 1/2, Bio-Rad, Marnes la Coquette, France) and a rapid dot blot test (Comb AIDS-RS, Span Diagnostics, Gujrat, India) were used for the sequential IAs. All samples which were repeat reactive by IA-1 were also confirmed by the gold standard confirmatory WB test (HIV W. BLOT, J Mitra and Co. Ltd, India). The results (positive, negative and indeterminate) of WB were analyzed as per WHO criteria.[7] Manufacturer′s instructions were strictly followed while performing each assay. The results of IA-1, IA-2 and IA-3 were compared with that of WB. The significance of S/C ratio (signal/cut off ratio) by repeat IA-1 was compared with WB reactivity pattern. Based on results of these sequential IAs and WB, a working algorithm for donor recall of true HIV seroreactive blood donors is suggested for countries like India where Nucleic Acid Testing (NAT) or p24 antigen assay are not mandatory and given the limited resources are not yet feasible.

Results

Out of 39,784 blood donor units screened during the study period, 64 were found to be HIV screen reactive by IA-1, thus accounting for a seroreactivity of 0.16%. Of the 64 reactive units, 44 (69%) were further tested by repeat IA-1, IA-2, IA-3 and WB tests. Twenty samples had been discarded and thus could not be retested. All forty four samples were repeat reactive by IA-1. Of these 44 samples, 32, 27 and 20 were IA-2, IA-3 and WB positive respectively as against the expected number of 46 (0.11%), 39 (0.098%) and 29 (0.07%) if adjusted for the discarded 20 samples. Thus, based on WB test, the true HIV seroprevalence of 0.07% is low in blood donors of Chandigarh.

According to the Action Plan for Blood Safety, all the 44 HIV 1/2 screen reactive blood donors should be notified of their TTD status.[3] However, for confirmation before donor recall, we tested IA-1 repeat reactive samples independently by two IAs based on different principles (IA-2 and IA-3). Comparison of seroreactivity performance of IA-2 and IA-3 with that of WB results on 44 IA-1 reactive samples is shown in [Table - 1]. Western blot positive, negative (BFR) and indeterminate results were found in 45.5% (n=20), 43.2% (n=19) and 11.3% (n=5) respectively, of the 44 IA-1 repeat reactive samples tested. Out of 44 IA-1 repeat reactive samples, 32 and 27 donors were found seroreactive by IA-2 and IA-3 respectively. Twenty one donors were found seroreactive independently by both IA-2 and IA-3 and 20 of these (95.2%) were WB positive. Seventeen donor samples found seroreactive by any one of these two IAs were either WB negative (n=13) or gave indeterminate (n=4) results.

Of the 44 repeatedly reactive blood donors, 96% (n=42) were males with a mean age (range) of 31.2 (19-51) years. The median S/C ratio was 2.35 with a range of 1.17 to 9.57. Thus, 22 reactive samples with S/C ratio less than 2.35 comprised the low positive group. 89.5% (17/19) of donor samples showing BFR had S/C ratio less than 2.35 as compared to 5% (1/20) for confirmed positives. Our results also suggest that if S/C ratio is high, the probability of it being positive by WB also increases as 86% (19/22) samples in this group were WB positive. Significance of S/C ratio with WB reactivity pattern is shown in [Figure - 1].

Comparison of seroreactivity by IA-1, IA-2 and IA-3 with WB results revealed that BFR [43.2% (19/44) vs. 25% (8/32) vs. 18.5% (5/27) respectively] and indeterminate results were observed in 11.3% (5/44) vs. 12.5% (4/32) vs. 7.4% (2/27) respectively. The most common cause of indeterminate results was non-specific reactivity to gag protein (p55 alone) in all five donors.

Based on the above results the recommended algorithm for donor recall of HIV screen reactive blood donors is summarized in [Figure - 2]. As compared to conventional strategy based on a single IA for donor recall, sequential IAs (IA-1, IA-2 and IA-3) results in selective donor referral for counseling to VCTC (44 vs. 25). Triple seroreactive (IA-1, IA-2 and IA-3) donors (n=21) can be recalled and referred to VCTC for donor counseling without WB test as none of them were BFR. However, all IA-1 reactive samples which are either IA-2 or IA-3 reactive (i.e. double reactive) require confirmation by WB before donor recall. This is because BFR and WB indeterminate results were observed with these double reactive samples [Table - 1]. This will also minimize WB usage (44 vs. 17). Thus, selective use of WB alongwith sequential IAs prevents BFR donors (43.2%) from unnecessary referral to VCTC.

Discussion

The primary purpose of screening donor blood for five mandatory infectious disease markers (anti-HIV 1/2, HBsAg, anti-HCV, VDRL and malaria) is to prevent pathogen transmission to recipients.[8] However, BTS on the other hand also have a "duty of care" to donors with adverse test results.[9] Failure to discharge this responsibility with due care can have serious consequences like negative impact of public confidence towards transfusion services and repeated rentry of infectious donors into safe donor pool.

The HIV seroprevalence based on single IA (IA-1) is low (0.16%) in our donor population in comparison to projected national figure (0.41%) by NACO[10] and other Indian studies (0.3% to 0.55%).[11],[12] However, true HIV seroprevalence of 0.07% in our study, based on ELISA and confirmatory WB is comparable to that reported in other Indian studies (0.02% to 1.2%).[13],[14],[15],[16],[17] Thus, without incorporating a confirmatory WB result the HIV seroprevalence from use of single ELISA test is certainly high, suggesting BFR or indeterminate results.

Low S/C ratio of an ELISA test can also suggest BFR.[18],[19],[20] We found S/C < 2.35 in 89.5% of donor samples showing BFR as compared to 5% for confirmed positives. Similar to our results, in another study 95.4% of BFR results had S/C ratio < 3 as compared to 0% for confirmed positive donors.[18]

In India, blood units that are HIV 1/2 reactive on screening IA are discarded (WHO Strategy-I) and the donor is notified about the test result if he/she has given the pre-donation consent for the same. Notification of false positive or indeterminate results has been reported to cause psychological distress and have negative social effects including disruption of family and work.[21],[22] This has lead to removal of a significant number of safe donations from the blood supply.[23] Each year, approximately 75,000 individuals in US are informed of having HIV-1 antibodies but less than 10% of these donors are truly infected on confirmatory test.[24],[25] Several factors (allergy, acute illness, alloimmunization, autoantibodies or vaccination) may be associated with HIV seroreactivity on a screen IA but a negative or indeterminate WB test.[26]

The BFR rate of an IA can vary significantly between different master lots from the same manufacturer.[27] However, we did not find such difference in HIV seropositivity on repeat ELISA from a different lot using the same manufacturer′s kit (repeat IA-1) and thus did not include this in our proposed algorithm.

A sample with a BFR result on one IA may give a negative result when retested with another assay when there is a minimal overlap (»5%) between the BFR populations of different IAs.[28] Therefore BFR results are often assay specific. This second IA being more specific must have sensitivity similar to that of IA-1. Thus, donor samples found seroreactive by three IAs without incorporating a WB test is a highly efficient and cost effective strategy in confirming true HIV positive blood donors who can be notified of their reactive status. Similarly donors who are non-reactive by both IA-2 and IA-3 may not be notified. This will prevent unnecessary notification to donors found false reactive by initial primary screen. Though these donors would not be notified, a strict follow up of their seroreactive behavior during subsequent donations is essential.

Management and notification of donors with indeterminate anti HIV WB becomes a critical situation for blood collection services. The commonest cause of indeterminate results on WB assays in voluntary blood donors is non-specific reactivity to gag proteins (p24, p55 and p17).[29],[30] We found p55 as the most common pattern seen on WB indeterminate results. Notification and follow up of ELISA reactive but WB indeterminate donors will help in clarifying their HIV status. In the developed countries, discriminatory tests for donor notification are based on highly sensitive and specific NAT assays.[31],[32] Confirmatory test using NAT on HIV screen reactive blood donors may not be feasible currently in under resourced countries. Fourth generation ELISA using combined antigen/antibody (p24/HIV antibody) assays have improved specificity and represent an alternative to separate antigen determination in diagnostic laboratory, blood donor screening and possibly to NAT in (mini)pools.[33],[34] Such studies from India on screen reactive donors may add new information to our proposed algorithm.

HIV infection has a tremendous psychosocial impact in Indian society. The stigma of being informed about HIV positive status creates personal and family stress. Our study suggests that HIV seroreactivity by sequential immunoassays (IA-1, IA-2 and IA-3) prior to donor recall results in decreased referral to VCTC (comparable to WHO Strategy-III) as compared to single IA (WHO Strategy-I) being followed currently in India. Moreover, this strategy will repose donor confidence in our blood transfusion services and strengthen voluntary blood donation program.

References

1.Kleinman S, Busch MP, Hall L, Thomson R, Glynn S, Gallahan D, et al . False-positive HIV 1 test results in a low-risk screening setting of voluntary blood donation. Retrovirus Epidemiology Donor Study. JAMA 1998;280:1080-5.  Back to cited text no. 1    
2.Wartick MG, McCarroll DR, Wiltbank TB. A second discriminator for biological false positive results in enzyme-linked immunosorbent assays for antibodies to human immunodeficiency virus (HTLV-III/LAV). Transfusion 1987;27:109-11.  Back to cited text no. 2  [PUBMED]  
3.An Action Plan for Blood Safety. National AIDS Control Organization, Ministry of Health and Family Welfare, Government of India; 2003. p. 35-7.  Back to cited text no. 3    
4.National AIDS Control Organization (NACO): Annual report on voluntary blood donors in India from 2002 to 31st July 2004. Ministry of Health & Family Welfare, Government of India.   Back to cited text no. 4    
5.World Health Organization (WHO). Nutritional anemia: Report of a WHO Scientific Group. Technical Report Series No. 405, WHO: Geneva; 1968.  Back to cited text no. 5    
6.World Health Organization (WHO). Nutritional anemia: Report of a WHO Scientific Group. Technical Report Series No. 580, WHO: Geneva; 1975.  Back to cited text no. 6    
7.Gallo D, Diggs JL, Shell GR, Dailey PJ, Hoffman MN, Riggs JL. Comparison of detection of antibody to the acquired immune deficiency syndrome virus by enzyme immunoassay, immunofluorescence and western blot methods. J Clin Microbiol 1986;23:1049-51.  Back to cited text no. 7    
8.Malik V. Drugs and Cosmetic Act, 1940. Eastern Book Company, 16th ed. 2003. p. 279-303.  Back to cited text no. 8    
9.Busch MP. To thy (reactive) donors be true! Transfusion 1997;37:117-20.  Back to cited text no. 9    
10.National AIDS Control Organization (NACO): Annual report on surveillance for HIV infection/AIDS cases in India from 2002 to 31st July 2004. Ministry of Health & Family Welfare, Government of India.  Back to cited text no. 10    
11.Makroo RN, Salil P, Vashist RP, Shivlal. Trends of HIV infection in blood donors of Delhi. Indian J Pathol Microbiol 1996;39:139-42.  Back to cited text no. 11    
12.Nanu A, Sharma SP, Chatterjee K, Joyti P. Markers for transfusion transmissible infections in north Indian voluntary and replacement blood donors: Prevalence and Trends 1989-96. Vox Sang 1997;73:70-3.  Back to cited text no. 12    
13.Choudhury N, Ayagiri A, Ray VL. True HIV Seroprevalence in Indian blood donors. Transfusion Med 2000;10:1-4.  Back to cited text no. 13    
14.Kapur S, Mittal A. Incidence of HIV infection and its predictors in blood donors in Delhi, India. J Med 1998;108:45-50.  Back to cited text no. 14    
15.Khurana SB, Ram S. Seroprevalence of blood donors and patients for HIV during 1988 to March 1997 at Ludhiana Punjab: HIV/AIDS research in India / editors Aggarwal OP, Sharma AK, Indrayan A: National AIDS Control Organization: New Delhi; 1998.p. 423-6.  Back to cited text no. 15    
16.Bhushan N, Pulimrod BR, Babu PG, John TJ. Rising trend in prevalence of HIV infection among blood donors. Indian J Med Res 1994;99:195-7.  Back to cited text no. 16    
17.Chatterjee R, Tarwater P, Neogi D, Ghosh A, Roy P, Sengupta S, et al . Estimation of HIV seroprevalence in blood bank camps in Kolkata, India. Transfusion Med 2004;14:77-8.  Back to cited text no. 17    
18.Kiely P, Stewart Y, Castro L. Analysis of voluntary blood donors with biologic false reactivity on chemiluminescent immunoassays and implications for donor management. Transfusion 2003;43:584-90.  Back to cited text no. 18    
19.Dufour DR, Talastas M, Fernandez MD, Harris B, Strader DB, Seeff LB. Low-positive Anti-Hepatitis C Virus Enzyme Immunoassay Results: An Important Predictor of Low Likelihood of Hepatitis C Infection. Clin Chem 2003;49:479-86.  Back to cited text no. 19    
20.Craske J, Turner A, Abbott R, Collier M, Gunson HH, Lee D, et al . Comparison of false positive reaction in direct binding anti HIV ELISA using cell lysate or recombinant antigens. Vox Sang 1990;59:160-6.  Back to cited text no. 20    
21.Guiltinan AM, Murphy EL, Horton JA, Nass CC, McEntire RL, Watanabe K. Psychological distress in blood donors notified of HTLV I/II infection. Retrovirus Epidemiology Donor Study. Transfusion 1998;38:1056-62.  Back to cited text no. 21    
22.Kleinman SH, Willams AE, Busch MP. Donor reactions to notification of abnormal test results (abstract). Transfusion 1999;39:113S.  Back to cited text no. 22    
23.Kiely P, Wood E. Can we improve the management of blood donors with nonspecific reactivity in viral screening and confirmatory assays? Transfusion Med Rev 2005;19:58-65.  Back to cited text no. 23    
24.Busch MP, Kleinman SH, Williams AE, Smith JW, Ownby HE, Laycock ME, et al . Frequency of human immunodeficiency virus (HIV) infection among contemporary anti HIV 1 and HIV 1/2 supplemental test - indeterminate blood donors. The Retrovirus Epidemiology Donor Study. Transfusion 1996;36:37-44.  Back to cited text no. 24    
25.Dodd RY, Stramer SL. Indeterminate results in blood donor testing: what you don't know can hurt you. Trans Med Rev 2000;14:151-60.  Back to cited text no. 25    
26.Celum CL, Coombs RW, Jones M, Murphy V, Fisher L, Grant C, et al . Risk factors for repeatedly reactive HIV 1 ELISA and indeterminate Western Blots: a population based case control study. Arch Intern Med 1994;154:1129-37.  Back to cited text no. 26    
27.Sharma UK, Stramer SL, Wright DJ, Glynn SA, Hermansen S, Schreiber GB, et al . Impact of changes in viral marker screening assays. Transfusion 2003;43:202-14.  Back to cited text no. 27    
28.Seed CR, Margaritis AR, Bolton WV, Kiely P, Parker S, Piscitelli L. Virology Subcommittee of the National Donor and Product Safety Committee, Australian Red Cross Blood Service. Improved efficiency of national HIV, HCV and HTLV antibody testing algorithm based on sequential screening immunoassays. Transfusion 2003;43:226-34.  Back to cited text no. 28    
29.Chattopadhya D, Aggarwal RK, Baveja UK, Doda V, Kumari S. Evaluation of epidemiological and serological predictors of human immunodeficiency virus type 1 (HIV 1) infection among high risk professional blood donors with western blot indeterminate results. J Clin Virol 1998;11:39-49.  Back to cited text no. 29    
30.Dock NL, Kleinman SH, Rayfield MA, Schable CA, Williams AE, Dodd RY. Human immunodeficiency virus infection and indeterminate western blot patterns. Prospective studies in a low prevalence population. Arch Intern Med 1991;151:525-30.  Back to cited text no. 30    
31.Busch MP, Glynn SA, Wright DJ, Hirschkorn D, Laycock ME, McAuley J, et al . National Heart, Lung, Blood Institute Nucleic Acid Test Study Group. Relative sensitivities of licensed nucleic acid amplification tests for detection of viremia in early human immunodeficiency virus and hepatitis C virus infection. Transfusion 2005;45:1853-63.  Back to cited text no. 31    
32.Koppelman MH, Assal A, Chudy M, Torres P, de Villaescusa RG, Reesink HW, et al . Multicenter performance evaluation of a transcription-mediated amplification assay for screening of human immunodeficiency virus-1 RNA, hepatitis C virus RNA and hepatitis B virus DNA in blood donations. Transfusion 2005;45:1258-66.  Back to cited text no. 32    
33.Canna F, Trevino E, Dominguez C, Gastaldello R, Barbas G, Cudola A, et al . Screening of HIV in blood banks. Evaluation of fourth generation kits. Medicina (B Aires) 2003;63:685-91.   Back to cited text no. 33    
34.Weber B, Gurtler L, Thorstensson R, Michl U, Muhlbacher A, Burgisser P, et al . Multicenter evaluation of a new automated fourth-generation human immunodeficiency virus screening assay with a sensitive antigen detection module and high specificity. J Clin Microbiol 2002;40:1938-46.   Back to cited text no. 34    

Copyright 2006 - Journal of Postgraduate Medicine


The following images related to this document are available:

Photo images

[jp06034f2.jpg] [jp06034f1.jpg] [jp06034t1.jpg]
Home Faq Resources Email Bioline
© Bioline International, 1989 - 2024, Site last up-dated on 01-Sep-2022.
Site created and maintained by the Reference Center on Environmental Information, CRIA, Brazil
System hosted by the Google Cloud Platform, GCP, Brazil