Case Report

Bilateral pleural effusions following central venous cannulation

Department of Radiology, John Radcliffe Hospital, Oxford, *Centre for Academic Surgery, Barts and London, Queen Mary's School of Medicine and Dentistry, University of London, UK
Correspondence Address:Department of Radiology, John Radcliffe Hospital, Oxford, pecklingtan@hotmail.com

Date of Submission: 12-Jan-2006
Date of Decision: 08-Jul-2006
Date of Acceptance: 13-Aug-2006

Code Number: jp07042

Abstract

We describe a patient who developed bilateral pleural effusions as a delayed complication following central venous catheter insertion. Respiratory distress should not only raise the clinical suspicion of a pneumothorax but also of erosion and perforation of the central vein. The mechanism, diagnosis, management and prevention of this complication are discussed.

Keywords: Central venous catheter complications, erosion, perforation, pleural effusion

This case highlights a rare but significant complication of central venous catheters (CVC). It is therefore important to recognize that despite correct initial placement of the CVC, late complications may still occur.[1] Specifically, this case demonstrates a deterioration of the patient′s condition due to erosion and penetration of the CVC tip through the superior vena cava several days later. Therefore, in the presence of a new onset pleural effusion, clinicians need to have a high index of suspicion of this complication.

Case History

A 20-year-old female with relapsing acute myeloid leukemia, was admitted for total body irradiation and bone marrow transplantation. Prior to commencement of treatment, a CVC (Kimal and Arrow InternationalTM, Middlesex, UK) was inserted via a left subclavian vein approach, using the Seldinger technique. Following insertion, blood was freely aspirated and good forward flow was tested to ensure no resistance to flow. In addition, a postprocedural chest radiograph confirmed satisfactory vertical catheter tip positioning in the superior vena cava (SVC).

Cyclophosphamide chemotherapy was subsequently started and it proceeded uneventfully until four days later when the patient complained of chest pain and breathlessness. A total volume of 7000 ml (a combination of cyclophosphamide infusion and continuous normal saline infusion) had been administered. A chest radiograph demonstrated a large right pleural effusion, a widened mediastinum but no pneumothorax. The CVC tip was noted to be displaced and located within the mediastinum. A computed tomography (CT) of the chest demonstrated a mediastinal fluid collection, bilateral pleural effusions and the CVC tip lying within the right pleural space [Figure - 1]. The CVC was removed via a standard well-described right common femoral venous approach. A chest drain inserted into the right pleural space and a needle thoracocentesis of the left pleural space, yielded two liters of straw-colored fluid with biochemical content consistent with 0.9% normal saline. The patient′s symptoms resolved following thoracocentensis.

Discussion

This case illustrates that despite initial correct CVC placement, a complication of pleural effusion became evident four days later, secondary to CVC tip erosion through the SVC, even in the absence of any specific risk factors. The CVC displacement may have potentially lethal complications[2],[3] but clinicians′ awareness is limited.[4] The tip of CVC should be within the SVC, above the pericardial reflection, to reduce the risk of vessel perforation and cardiac tamponade. Despite advances in technique and design, CVC erosion remains a rare[1] but significant clinical problem.[2],[4] Clinical manifestations vary with the size and speed of onset of the pleural effusion, usually related to cardio-respiratory compromise.

The content of the left pleural effusion was identical to that of the right suggesting either a congenital interpleural communication or fluid dissipation through the mediastinum from one pleural space to the other. The pleural fluid contained no red blood cells. Thus is surprising but plausible that a thrombus formed around the erosion site may have prevented any clinically evident hemorrhage.[5]

Numerous factors influencing the risk of perforation have been described. Stiffer catheters and those with excessively mobile tips are reported to increase the risk of vessel perforation.[6] The angle formed by the catheter tip and the vein wall is important, the more perpendicular the angle, the greater the risk of perforation.[7],[8] Left-sided catheters themselves pose a particular problem as the left brachiocephalic vein forms a near right angle with the SVC, increasing the risk of impingement.[7],[8] High-pressure fluid infusion is also a risk factor. It is likely that some perforations are secondary to guide wire or dilator trauma, particularly when complications occur soon after insertion.

Vessel perforation should be suspected if there is a curved appearance of the distal catheter,[9] an atypical catheter course, pneumothorax, mediastinal widening, pleural effusion, hemothorax or pneumomediastinum. CT would be diagnostic.

Several lessons can be learnt from this case. Firstly, the left side approach should be avoided but if required, the CVC should be advanced far enough into the SVC so that it lies parallel with the vessel wall. Secondly, any unexplained respiratory deterioration must arouse suspicion of catheter erosion and clinicians should recognize the development of a pleural effusion as a potential delayed complication, days after apparently successful CVC placement. Early evaluation by pleural aspiration or drainage is both diagnostic and therapeutic. The use of ultrasound guidance for CVC placement is supported by meta-analysis [10],[11] which suggests a significantly reduced failure rate of cannulation, decreased need for multiple attempts, more rapid access and reduced complications during insertion. However, the use of ultrasound would not have prevented the particular complication described.

References

1.Robinson JF, Robinson WA, Cohn A, Garg K, Armstrong JD 2nd. Perforation of the great vessels during central venous line placement. Arch Intern Med 1995;155:1225-8.  Back to cited text no. 1  [PUBMED]  
2.Collier PE, Blocker SH, Graff DM, Doyle P. Cardiac tamponade from central venous catheters. Am J Surg 1998;176:212-4.  Back to cited text no. 2  [PUBMED]  [FULLTEXT]
3.Dane TE, King EG. Fatal cardiac tamponade and other mechanical complications of central venous catheters. Br J Surg 1975;62:6-10.  Back to cited text no. 3  [PUBMED]  
4.Collier PE, Goodman GB. Cardiac tamponade caused by central venous catheter perforation of the heart: A preventable complication. J Am Coll Surg 1995;181:459-63.  Back to cited text no. 4  [PUBMED]  
5.McDonnell PJ, Qualman SJ, Hutchins GM. Bilateral hydrothorax as a life-threatening complication of central venous hyperalimentation. Surg Gynecol Obstet 1984;158:577-9.  Back to cited text no. 5  [PUBMED]  
6.Gravenstein N, Blackshear RH. In vitro evaluation of relative perforating potential of central venous catheters: Comparison of materials, selected models, number of lumens and angles of incidence to simulated membrane. J Clin Monit 1991;7:1-6.  Back to cited text no. 6  [PUBMED]  
7.Dailey RH. Late vascular perforations by CVP catheter tips. J Emerg Med 1988;6:137-40.  Back to cited text no. 7  [PUBMED]  
8.Mukau L, Talamini MA, Sitzmann JV. Risk factors for central venous catheter-related vascular erosions. JPEN J Parenter Enteral Nutr 1991;15:513-6.  Back to cited text no. 8  [PUBMED]  
9.Tocino IM, Watanabe A. Impending catheter perforation of superior vena cava: Radiographic recognition. AJR Am J Roentgenol 1986;146:487-90.  Back to cited text no. 9  [PUBMED]  
10.Hind D, Calvert N, McWilliams R, Davidson A, Paisley S, Beverley C, et al . Ultrasound locating devices for central venous cannulation: Meta-analysis. BMJ 2003;327:361.  Back to cited text no. 10    
11.Randolph AG, Cook DJ, Gonzales CA, Pribble CG. Ultrasound guidance for placement of central venous catheters: A meta-analysis of the literature. Crit Care Med 1996;24:2053-8.  Back to cited text no. 11  [PUBMED]  [FULLTEXT]

Copyright 2007 - Journal of Postgraduate Medicine


The following images related to this document are available:

Photo images

[jp07042f1.jpg]
Home Faq Resources Email Bioline
© Bioline International, 1989 - 2024, Site last up-dated on 01-Sep-2022.
Site created and maintained by the Reference Center on Environmental Information, CRIA, Brazil
System hosted by the Google Cloud Platform, GCP, Brazil