search
for
 About Bioline  All Journals  Testimonials  Membership  News


Journal of Postgraduate Medicine
Medknow Publications and Staff Society of Seth GS Medical College and KEM Hospital, Mumbai, India
ISSN: 0022-3859 EISSN: 0972-2823
Vol. 54, Num. 1, 2008, pp. 4-6

Journal of Postgraduate Medicine, Vol. 54, No. 1, January-March, 2008, pp. 4-6

Original Article

Detection of Rh antibodies using two low ionic diluents: Extension of the incubation time and the number of Rh antibodies detected

Department of Laboratory Medicine, Al-Azhar University - Gaza, Gaza, Palestine. 16/46 Omar Al-Mokhtar Street, AL-Rimal, Gaza, Palestine
Correspondence Address:Department of Laboratory Medicine, Al-Azhar University - Gaza, Gaza, Palestine. 16/46 Omar Al-Mokhtar Street, AL-Rimal, Gaza, Palestine, y_skaik@hotmail.com

Date of Submission: 08-Aug-2007
Date of Decision: 13-Nov-2007
Date of Acceptance: 05-Dec-2007

Code Number: jp08002

Abstract

Background: Low ionic strength solution (LISS) is used to increase the rate of association of antibody to the corresponding antigen during antibody detection tests. A number of LISSs are available on the market.
Aims:
The efficiency of two commercial low ionic diluents, DiaMed ID-CellStab and Inverclyde LISS were assessed using the DiaMed-ID LISS Coombs microtube column system and an incubation time varying from 15 to 35 min.
Materials and Methods:
One-hundred samples containing five Rh antibodies (anti-D, anti-C, anti-E, anti-c and anti-e) were tested against commercial red cells using the two low ionic diluents after 15, 25 and 35 min.
Results:
The Inverclyde LISS detected 91, 95 and 96% of the Rh antibodies compared to 78, 79 and 83% for ID-CellStab after 15, 25 and 35 min incubation time, respectively, for both methods.
Conclusions:
The Inverclyde LISS is a more suitable and efficient diluent than ID-CellStab for the detection of Rh antibodies. The sensitivity of Rh antibody detection increased for the both methods as the incubation time increased.

Keywords: Antibody affinity, haemagglutination, Rh antibody detection, Rh-Hr, immunoglobulin G

Rh antibodies are formed when an individual is exposed to foreign Rh antigens through transfusion or pregnancy. These antibodies are clinically significant, [1] react best at 37°C and they should be considered potentially capable of causing both haemolytic transfusion reactions (HTRs) and haemolytic disease of the newborn (HDN). [2],[3] Their detection is not always reliable because the persistence of antibodies at detectable level varies among people and even within the spectrum of Rh antibodies [4],[5],[6],[7],[8],[9],[10] and they have a low affinity. [11] The use of screening red cells with homozygous expression of rhesus antigens is recommended [12] to maximise antibody detection. Most laboratories use enhancement media (LISS) to decrease incubation time from 60 or 90 min to 15 or 20 min, to enhance RBC sensitization, decreased number of false-positive results [13],[14],[15],[16],[17] and increase the sensitivity of the assay. In 1953, Jerne and Skovsted [18] described the effect of low ionic strength solution (LISS) on the antigen antibody reaction. The value of lowering the ionic strength of the medium was also demonstrated using anti-D with D-positive red blood cells (RBCs). [13] However, LISS did not find favour in practical work because of the occurrence of nonspecific positive reactions. In the wake of the failure and poor performance of LISS, Lφw and Messeter [14] placed LISS in the incubation phase of the indirect antiglobulin test (IAT) on the threshold of using LISS in the routine practice.

Several brands of commercial LISS are available on the market. However, controversy exists concerning the efficiency of one of these, ID-CellStab (DiaMed, Switzerland), which is widely used in detecting red cell alloantibodies. [19],[20],[21] The present study has two aims: first, to confirm our previous results [21] that compared the sensitivity of two low ionic diluents (Inverclyde LISS and ID-CellStab) in the detection of a spectrum of antibodies and second, to investigate the value of extending the incubation time up to 35 min with both diluents using DiaMed ID LISS/Coombs microcolumn system. [22] The incubation time was only limited to 35 min, first the samples were not sufficient and second, to avoid false positive results, as extending the incubation time longer than 40 min, may result in a loss of sensitivity. [23]

Materials and Methods

Subjects

Sera, known to contain anti-D, anti-C, anti-E, anti-c or anti-e antibodies, from 100 patients were tested. All antibodies under investigation were previously identified by IAT in routine antibody screening, using ID-CellStab, enzyme method, polyethylene glycol (PEG) or polybrene technique. An autocontrol was used in the original identification to avoid false positive reactions. All patients were informed about the goal of the study and consented to the use of their sera for further transfusion laboratory investigations. All samples were stored in a frozen state at -35°C after the original identification by an expert biomedical scientist, thawed immediately before use and allowed to reach the room temperature.

Red cell samples and suspensions

Commercially available red cells (National Blood Service, Cambridge Hospital, UK) were used. For each antibody specificity tested, two positive and two negative cell suspensions were used except anti-e, where one negative cell only was used [Table - 1]. The RBC suspensions were prepared using 50 µL of the commercial red cells, washed three times either with ID-CellStab (DiaMed, Switzerland) or Inverclyde LISS (Inverclyde Biologicals, Scotland) and resuspended in approximately 5 mL of the respective diluent in a clean glass tube to obtain 1%, in accordance with manufacturer′s instructions of the DiaMed technique. All RBC suspensions were prepared afresh on the day of use.

Indirect antiglobulin test

Fifty microlitres of 1% RBCs suspended in ID-CellStab or Inverclyde LISS and 25 µL of serum were added to the DiaMed-ID LISS/Coombs′ gel (containing polyspecific anti-IgG and anti-C3d) and incubated for 15, 25 and 35 min at 37°C (DiaMed-ID Incubator 37 SI) followed by centrifugation at 1000 g (DiaMed ID-centrifuge 245 SII) for 10 min. All positive reactions were graded macroscopically from 1+ to 4+ using 1+ as an increment. All tests and interpretations were personally performed.

Controls

AB serum (NBS, Cambridge Hospital, UK): as a negative control.

Two positive and two negative cells (NBS, Cambridge Hospital, UK): for each antibody specificity with the exception of anti-e, where one negative cell suspension was used.

Different lot numbers of ID-Panel (NBS, Cambridge Hospital, UK): was used to repeat the test in the case of discrepancy between the two diluents.

Results

For each antibody specificity tested, the Inverclyde LISS detected a greater number of antibodies than ID-CellStab [Table - 2]. The total number of antibodies detected after 15 min incubation, using Inverclyde LISS was 91 out of 100 compared to 78 detected by CellStab [Figure - 1]. The extension of the incubation time from 15 to 35 min showed an increase of 6% in the total number of antibodies detected using both low ionic diluents. For ID-CellStab, there was no increase in the antibody detection as the incubation time increased from 15 to 25 min with the exception of one case of anti-E [Table - 2]. Four additional antibodies were identified using Inverclyde LISS at 25 min incubation. Four were detected using ID-CellStab when the incubation time reached 35 min. Only one additional case of anti-E was identified using Inverclyde LISS as the incubation time was extended to 35 min. Therefore, 96% of Rh antibodies tested were detected using Inverclyde LISS after 35 min compared to 83% identified by ID-CellStab [Figure - 1]. Thirteen antibodies were reactive in Inverclyde LISS, but missed in the ID-CellStab after 35 min incubation at 37°C [Table - 2]. These antibodies were originally detected by the enzyme method, PEG or polybrene technique. For every antibody tested, no discrepancies were recorded in the positive or negative cells and there were no positive reactions with AB serum. No false positive reaction occurred due to a specific antibody binding after extending the incubation time up to 35 min. In addition, no discrepancy was found between the different batches of the ID-Panel. The reaction strength varies from 1+ to 2+ using Inverclyde LISS vs. ID-CellStab.

Discussion

The Inverclyde LISS detected 91, 95 and 96% of the Rh antibodies compared to 78, 79 and 83% for ID-CellStab after 15, 25 and 35 min incubation time, respectively, for both methods. The present study confirmed our previous findings on the relative merits of the two diluents [21] and demonstrated the improved sensitivity in the detection of Rh antibodies by extending the incubation period. We found in our previous study that the Inverclyde LISS detected greater number of Rh antibodies (four anti-D, four anti-E and one anti-C) than did CellStab after 15 min using the DiaMed gel test. It should be noted that in a study by Grey et al. , [19] ID-CellStab was shown to be less efficient than the two other diluents (not including Inverclyde LISS). The missing of thirteen antibodies (five anti-D, two anti-C, four anti-E, one anti-c and one anti-e) using ID-CellStab after 15 min may be attributed to the high percentage of sodium azide and/or increase of both osmolality and conductivity [19],[20],[21],[22],[23] of the diluent. Therefore, suboptimal binding of the Rh antibody within short incubation period occurred. The nine antibodies that were missed in both diluents may be due to insensitivity of the gel technique, [24] inappropriate volumes or percentage, specificity of the antibody, the inhibitory effect of the gel matrix [25] and the incubation time. [11] The present study adds further weight to the argument that the Inverclyde LISS is a suitable and more efficient than ID-CellStab for the detection of Rh antibodies.

Furthermore, the sensitivity of Rh antibodies detection increased as the incubation time increased.

Acknowledgments

I would like to commend for the generous assistance of Dr. David Britt, who revised grammatically and help in the preparation of the manuscript. I wish also to thank Mr. Hamed AL-Hefny, who provided the blood samples.

References

1.Garratty G. Evaluating the clinical significance of blood group alloantibodies that are causing problems in pretransfusion testing. Vox Sang 1998;74:285-90.  Back to cited text no. 1  [PUBMED]  [FULLTEXT]
2.Daniels G, Poole J, de Silva M, Callaghan T, MacLennan S, Smith N. The clinical significance of blood group antibodies. Transfus Med 2002;12:287-95.  Back to cited text no. 2  [PUBMED]  [FULLTEXT]
3.SHOT. The serious Hazards of Transfusion. Annual report. SHOT office. National Blood Service, Manchester Blood Center, The Biomedical Scientist: 2004. p. 840-3.  Back to cited text no. 3    
4.Ward HK. The persistence of antibodies in the absence of antigenic stimulus. Aust J Exp Biol Med Sci 1957;35:499-506.  Back to cited text no. 4  [PUBMED]  
5.Hopkins DF. The decline and fall of anti-Rh(D). Br J Haematol 1969;17:199-204.  Back to cited text no. 5  [PUBMED]  
6.Ramsey G, Larson P. Loss of red cell alloantibodies over time. Transfusion 1988;28:162-5.  Back to cited text no. 6  [PUBMED]  
7.Rosse WF, Gallagher D, Kinny TR, Castro O, Dosik H, Moohr J, et al . Transfusion and alloimmunisation in sickle cell disease: The Cooperative Study of Sickle Cell Disease. Blood 1990;76:1431-7.  Back to cited text no. 7    
8.Ramsey G, Smietana S. Long-term follow-up testing of red cell alloantibodies. Transfusion 1994;34:122-4.  Back to cited text no. 8    
9.Schonewille H, Haak H, van Zijl A. Alloimmunisation after blood transfusion in patients with haematologic and oncologic diseases. Transfusion 1999;39:763-71.  Back to cited text no. 9    
10.Hutchison HE, McLennan W. Long persistence of rhesus antibodies. Vox Sang 1966;11:517-8.  Back to cited text no. 10  [PUBMED]  
11.American Association of Blood Banks. Red cell antigen-antibody reactions and their detection. American association of Blood Banks Technical Manual, 12 th ed. AABB: Maryland; 1999.  Back to cited text no. 11    
12.BCSH Blood Transfusion Task Force. Guidelines for pre transfusion compatibility procedures in blood transfusion laboratories. Transfus Med 1996;6:273-83.  Back to cited text no. 12    
13.Hughes-Jones NC, Gardener B, Telford R. The effect of pH and ionic strength on the reaction between anti-D and erythrocytes. Immunology 1964;7:72-81.  Back to cited text no. 13    
14.Lψw B, Messeter L. Antiglobulin test in low-ionic strength salt solution for rapid antibody screening and cross-matching. Vox Sang 1974;26:53-61.  Back to cited text no. 14    
15.Elliot M, Bossom E, Dupuy MD, Masouredis SP. Effect of ionic strength on the serologic behavior of red cell isoantibodies. Vox Sang 1964;9:396-414.  Back to cited text no. 15    
16.Moore HC, Mollison, PL. Use of a low-ionic-strength medium in manual tests for antibody detection. Transfusion 1976;16:291-6.  Back to cited text no. 16    
17.Wicker B, Wallas CH. A comparison of a low ionic strength saline medium with routine methods for antibody detection. Transfusion 1976;16:469-72.  Back to cited text no. 17    
18.Jerne NK, Skovested L. The rate of inactivation of becteriophage T4r in specific anti-serum, I, Salt effect, II: Cofactor. Ann Inst Pasteur (Paris) 1953;84:73-89.  Back to cited text no. 18    
19.Grey D, Connolly M, Erber W. Comparison of low ionic diluents for use with the DiaMed antiglobulin gel test. Transfus Med 2002;12:63-9.  Back to cited text no. 19    
20.Bromilow IM. Low ionic diluents and the DiaMed antiglobulin test. Transfus Med 2002;12:329.  Back to cited text no. 20    
21.Skaik YA, Overfield J. Detection of red cell antibodies: Comparison of two low ionic strength diluents. Br J Biomed Sci 2006;63:18-20.  Back to cited text no. 21    
22.Jψrgensen J, Nielsen M, Nielsen CB, Nψrmak J. The influence of ionic strength, albumin and incubation time on the sensitivity of the indirect Coombs' test. Vox Sang 1979;36:186-91.  Back to cited text no. 22    
23.Phillips PK, Bebbington C. The pH, conductivity and osmolality of low ionic strength solutions used within UK for the antiglobulin test. Transfus Med 1991;1:155-8.   Back to cited text no. 23    
24.Phillips PK, Whitton C, Lavin F. The use of the antiglobulin 'gel-test' for antibody detection. Transfus Med 1992;2:111-3.  Back to cited text no. 24    
25.Phillips P, Voak D, Knowles S, Campbell G, Crane B, Downie DM, et al . An explanation and clinical significance of the failure of microcolumn tests to detect weak ABO and other antibodies. Transfus Med 1997;7:47-53.  Back to cited text no. 25    

Copyright 2008 - Journal of Postgraduate Medicine


The following images related to this document are available:

Photo images

[jp08002t1.jpg] [jp08002f1.jpg] [jp08002t2.jpg]
Home Faq Resources Email Bioline
© Bioline International, 1989 - 2024, Site last up-dated on 01-Sep-2022.
Site created and maintained by the Reference Center on Environmental Information, CRIA, Brazil
System hosted by the Google Cloud Platform, GCP, Brazil