search
for
 About Bioline  All Journals  Testimonials  Membership  News


Brazilian Journal of Oral Sciences
Piracicaba Dental School - UNICAMP
EISSN: 1677-3225
Vol. 6, Num. 20, 2007, pp. 1278 - 1282

Brazilian Journal of Oral Sciences, Vol. 6, No. 20, January - March 2007, pp. 1278 - 1282

Comparative radiopacity of four low-viscosity composites

Micheli Tavares Imperiano 1 , Helen Jamil Khoury 2 , Maria Luiza Anjos Pontual 3 , Marcos Antonio Japiassú Resende Montes 1 , Márcia Maria Fonseca da Silveira 3

1 Department of Restorative Dentistry / Dental Materials, School of Dentistry of Pernambuco-UPE, Camaragibe-PE, Brazil.
2 Department of Nuclear Engineering, Federal University of Pernambuco-UFPE, Recife-PE, Brazil.
|3 Department of Oral Medicine / Oral Diagnosis, School of Dentistry of Pernambuco-UPE, Camaragibe-PE, Brazil.
Correspondence to: Marcos Antonio Japiassú Resende Montes Av. Gen Newton Cavalcanti, 1650 Camaragibe-PE - 54753-220 - Brazil. Phone: +55-81-3458-1186 Fax: +55-81-3458-1476 E-mail: majrm@uol.com.br

Received for publication: November 14, 2006
Accepted: February 15, 2007

Code Number: oc07007

Abstract

The aim of this study was to evaluate the radiopacity of four commercially available low-viscosity composites. The low-viscosity composites used in this study were Natural Flow, Flow It, Filtek Flow and Protect Liner F. Five specimens of each material were made in stainless-steel ring moulds of 10 mm diameter and 2 mm height. One specimen of each material and a 10-step aluminium wedge were radiographed in an occlusal film. The reading of the optical density was performed in five different locations in each radiographed specimen. The net optical density was calculated, and then the mean values were obtained, and related with the equivalent thickness of aluminium. The radiopacities of each composite, in millimeters of aluminium were: Flow It (3.24 ± 0.17); Filtek Flow (2.25 ± 0.17); Natural Flow (1.50 ± 0.13); Protect Liner F (<1 mm/Al). Flow It and Filtek Flow presented an acceptable radiopacity according to the ISO Standard 4049. Natural Flow and Protect Liner F did not supply the requirements for radiopacity, thus, these materials could be confounded with secondary caries in some clinical applications, such as restorations or cavity lining.

Key Words: low-viscosity composites, X-Ray, densitometry, radiopacity, diagnosis

Introduction

The first generation of low-viscosity composites was introduced in late 1996, just before condensable composites, being developed in response to requests for special handling characteristics, rather than for any performance criteria, and with unknown limitations. These materials were created by retaining the same particle size of traditional hybrid composites, but reducing the filler content and increasing the proportion of diluent monomers in its formulation, reducing its viscosity1. They were recommended due to the higher flow, which allowed easier insertion in some clinical situations, an improved adaptation in internal cavity walls, particularly in deeper cavity angles, and greater elasticity than previously available products. Low-viscosity composites have been used for a wide range of applications, from liners and pit/fissure sealants to margin or void repairs, and even for class I and V restorations1-12.

According to the American Dental Association, Council on Dental Materials, Instruments and Equipment13, a dental filling must accomplish five basic requirements: high wear resistance; good marginal adaptation; resistance to hydrolytic degradation and other solvents; radiopacity; and easiness of execution.

Radiopacity is an essential property for all restorative materials13-15. In restorative dentistry, a radiopaque filling material would allow the dentist to distinguish, radiographically, existing restorations and primary caries, to evaluate contours, overhangs, and major voids in restorations, and to assist in the identification of recurrent caries13-14,16-18.

There are several studies on the radiopacity of composites in the literature14-22, however, few studies are available regarding the radiopacity of low-viscosity composites18,21,23-24. Thus, the aim of this study was to evaluate this property in four commercially available low-viscosity composites.

Material and Methods

The materials, manufacturers, compositions and batch numbers for this study are listed in Table 1. The low-viscosity composites were tested for radiopacity in accordance with the International Standards Organization ISO 404925.

A stainless-steel ring mould with an internal diameter of 10 mm and 2 mm height was used to prepare standardized specimens. Five specimens of each material were made by inserting the material slowly into the ring mould using the manufacturer's syringe tip applier, in order to avoid the occurrence of bubbles inside the specimens after polymerization. After the complete filling of the ring mould, the specimens were polymerized using a visible light-curing unit (Ultralux EL, Dabi Atlante Co. Ribeirão Preto SP, Brazil) for 60 seconds on the top surface and then inverted and light cured on the bottom surface for an additional 60 seconds. The specimens were finished with 600-grit SiC paper under water, separated from the moulds and individually polished with fine and superfine flexible Soft-Lex discs. The specimens' thicknesses were verified with a digital micrometer in order to ensure standardization.

After preparation, the specimens were radiographed (Insight, Kodak, Eastman Rochester, USA) to check the porosity content. Specimens with porosities were excluded from the study and replaced. The specimens were then stored in distilled water at 37o C for one week. Then the radiographic procedures were conducted.

One specimen of each material and the 10-step aluminium wedge were placed on an occlusal dental film (Insight, Kodak, Eastman Rochester, USA. Batch 2106666). The X-ray unit (GRD, Heliodent 60B, Siemens, Germany) was set at 65 kVp, using a current of 10 mA, and a 1-second standard exposure time. The focus-film distance was set at 40 cm. The exactness and precision of the X-ray equipment were previously evaluated, with the deviation values lower than 3% for the tension variation applied to the X-ray tube, and for the reproducibility of the radiographs.

A densitometer (M. R. A., Brazil) was then used to record the readings of the radiographic images of the specimens, the 10-step aluminium wedge, and the unexposed part of the film (Fig. 1). Five readings were recorded for each film and each material, and the mean was subsequently calculated. The net radiographic density was derived from the following equation: net radiographic density = gross radiographic density (base + fog).

The aluminium equivalent thickness (mm) for each material was calculated from the linear regression equation of the log of normalized optical density and aluminium thickness (mm) obtained from the 10-step wedge. Table 2 displays the equations resulting from the graphs of each radiographic film exposed for the determination of the radiopacity of each material, expressed in millimeters of aluminium.

Results

Table 3 summarizes the mean radiopacity of the materials, the mean equivalent of aluminium thickness as well as standard deviations. Flow It (3.24 mm/Al) was the most radiopaque of the materials evaluated, followed by Filtek Flow (2.25 mm/Al); Natural Flow (1.5 mm/Al) and Protect Liner F, which presented a net density value of lower than the equivalent of 1 millimeter thickness of aluminium.

Discussion

Radiopacity of dental materials has been evaluated by several techniques. Schoenfeld et al.26 developed a theoretical model for predicting materials' optical densities, when given a set of radiographic variables. Other authors have used the simpler technique of comparing specific thicknesses of composite to aluminium step wedges or aluminium standards under typical radiographic conditions14,18-19,21,27-29. Human tooth tissues may perform better as a standard than aluminium; however, the natural variability between distinct conditions of development, film and exposure may interfere with, and make difficult, comparisons among different studies. In this study, the comparison of radiopacity values was conducted with aluminium as the reference. The literature shows a great variability in the radiopacity of dental tissues, and the mean radiopacity of 2 mm of enamel ranges from 2.5 mm/Al18 to 3.53 mm/Al30, whilst for dentin it ranges from 1.5 mm/Al18 to 1.99 mm/Al21. Restorative materials that present a lower radiopacity, or even equivalent radiopacity, to the tooth structure must be avoided for posterior restorations, since an enhanced radiopacity would enable the easy detection of the interface between the filling and enamel or dentin18,20,22,30. Furthermore, ISO standards25 stipulate that the minimum radiopacity for a restorative material should be equal or higher than its equivalent thickness in aluminium. For this study a 2 mm thickness was used.

Several studies have suggested that the radiographic detection of caries is improved if radiopacity of the restorative material is similar or slightly greater than the enamel's31-32. According to Goshima20, it would be preferable if the composite resins had a higher degree of radiopacity, similar to amalgam. However, it has been reported that the extreme radiopacity of amalgam does not provide the best conditions for radiographic detection of caries and defects adjacent to restorations, as compared to posterior composites, since its very high radiopacity interferes directly in the contrast, impairs visual acuity and, consequently, diminishes the perception of details17. Thus, the appropriate degree of radiopacity for restorative materials remains open for discussion, since differences in radiopacity values between structures indicate that problems of interpretation may occur in the clinical situation; it is, however, questionable whether a statistical difference in radiopacity between two materials can be seen as contrast on a radiograph. In this respect, radiograph and cognitive factors alike should be taken into account33.

Radiolucent incipient images in enamel are hardly detected by radiographic examination, due to the superposition of healthy enamel, since variations in thickness of materials may influence the resultant radiopacity, although this is less important than its molecular structure34. In fact, this could result in a difficult visualization of radiolucent images corresponding to small cavities filled with less radiopaque materials than the enamel; thus, when the caries is restricted to enamel, it would be preferable to use a material with higher radiopacity than enamel, and it may be stated that the optical density of materials is critical in small cavities that have a large amount of remaining dental structure, since materials are applied with a lower thickness33-34.

A plethora of new low-viscosity composites have been marketed during the last 8 years, and it could be said that almost all the composite manufacturers have at least one commercially available low-viscosity composite. Many dentists have accepted these flowable composites for a wide variety of uses. These materials have been reported to adapt well to cavity walls, and that this optimal adaptation could result in an improvement in the adhesive performance in composite restorations9. Indeed, one of the most recommended applications has been its use as a cavity liner, on the adhesive surface, in order to create a lower elastic modulus intermediate layer along the cavity wall, diminishing the effect of the rigid polymerization shrinkage of the restoring composite2-5,7-12. Particularly for this clinical application, the radiopacity of these materials become a decisive factor, since there is a tendency for accumulation in deeper cavity angles, due the material's high flow, which could lead to misinterpretations in radiographic diagnosis, suggesting lack of material and remaining or recurrent caries. According to Unterbrink and Liebenberg7, the use of highly radiopaque low-viscosity composites on adhesive surfaces would avoid misinterpretations during the radiographic diagnosis of composite restorations.

Watts15 found that radiopacity values of higher than those in enamel may be achieved in composites with a filler loading of approximately 70% by volume when the mass percentage of radiopaque oxide in the filler exceeds about 20%. All the low-viscosity composites evaluated in the study presented a lower filler loading (Table 1), and only Flow It (3.24 mm/Al) presented an equivalent or superior radiopacity to the enamel's. (Table 3)

Flow It, a first-generation low-viscosity composite, with silica and barium boro-fluoro-silicate glass (and a trace amount of aluminium oxide) as its filler, a mean filler particle size of 1 µm diameter and a filler content of 66% by weight and 51% by volume, presented the highest radiopacity among the tested composites, corroborating the results of Bouschlicher et al.21 and Murchison et al.18. This composite presents the highest filler content among the materials investigated by this study and, according to Bayne et al.1, its physical properties are similar to those of the traditional hybrid composites. Indeed, its higher filler content associated with the high atomic number element barium, and the trace amount of aluminium oxide, improved its radiopacity which is within that recommended by ISO 4049, and meets the values of enamel's radiopacity reported in the literature18,30. Thus, according to this property, Flow It could be indicated for lining in traditional composite restorations in posterior teeth.

The low-viscosity composite, Filtek Flow, presents a 68% by weight and 47% by volume of zirconium/silica filler, with a mean particle size of 1.5 µm. This filler is the same as the traditional micro-hybrid composites Z-100 and Z-250 of the same manufacturer. Its radiopacity corresponded to 2.24 mm/Al, which is higher than dentin's radiopacity. Thus, according to ISO 4049, this composite fulfils the requirements for application as a liner in posterior teeth restorations.

Natural Flow (1.5 mm/Al) and Protect Liner F (<1 mm/Al) presented lower radiopacities than the correspondent in mm/Al of dentin, and lower than the ISO 4049 recommendations. According to Sabbagh et al.24, the radiopacity of composite resins is dependent on their fillers (percentage and type). Although Natural Flow presents the same type of filler as Filtek Flow, i.e., zirconium/silica, its lower content (54% by weight and 41% by volume) must have been decisive to its lower radiopacity. Protect Liner F is a microfilled composite, thus its filler particle is silanized colloidal silica and prepolymerized organic filler. Regardless of its filler content which is 42% by weight, the type of filler determined its low radiopacity, and is explained by the unique presence of the low atomic number element silicon in its filler composition. Indeed, materials composed by elements with low atomic numbers, such as silicon, resulted in radiolucent materials, while the addition of elements with high atomic numbers (Barium, Yttrium and Ytterbium), resulted in radiopaque composites24. In this case, the use of the low-viscosity composites Natural Flow and Protect Liner F could compromise radiographic diagnosis, leading the clinician to confound them with lack of material, marginal leakage, and remaining or secondary caries.

References

  1. Bayne SC, Thompson JY, Swift EJ Jr, Stamatiades P, Wilkerson M. A characterization of first-generation flowable composites. J Am Dent Assoc. 1998; 129: 567-77.
  2. Swift EJ Jr, Triollo PT Jr, Barkmeier WW, Bird JL, Bounds SJ. Effect of low-viscosity resins on the performance of dental adhesives. Am J Dent. 1996; 9: 100-4.
  3. Rada RE. The versatility of flowable composites. Dentistry Today. 1998; 17: 78-83.
  4. Prager MC. Using flowable composites in direct posterior restorations. Dent Today. 1997; 16: 62-9.
  5. Behle C. Flowable Composites: properties and applications. Dent News Sci. 1998; 10: 347-51.
  6. Payne JH 4th. The marginal seal of class II restorations: flowable composite resin compared to injectable glass ionomer. J Clin Pediatr Dent. 1999; 23:123-30.
  7. Unterbrink GL, Liebenberg WH. Flowable resin composites as "filled adhesives": Literature review and clinical recommendations. Quintessence Int. 1999; 30: 249-57.
  8. Montes MAJR, de Goes MF, Cunha MRB, Soares AB. A morphological and tensile bond strength evaluation of an unfilled adhesive with low-viscosity composites and a filled adhesive in one and two coats. J Dent. 2001; 29: 435-41.
  9. Frankenberger R, Lopes M, Perdigão J, Abrose WW, Rosa BT. The use of flowable composites as filled adhesives. Dent Mater. 2002; 18: 227-38.
  10. Braga RR, Hilton TJ, Ferracane JL. Contraction stress of flowable composite materials and their efficacy as stress-relieving layers. J Am Dent Assoc. 2003; 134: 721-8.
  11. Montes MAJR, de Goes MF, Ambrosano GMB, Duarte RM, Sobrinho LC. The effect of collagen removal and the use of a low-viscosity resin liner on marginal adaptation of resin composite restorations with margins in dentin. Oper Dent. 2003; 28: 378-87.
  12. Reis AF, Giannini M, Ambrosano GMB, Chan DCN. The effects of filling techniques and a low-viscosity composite liner on bond strength to class II cavities. J Dent. 2003; 31: 59-66.
  13. American Dental Association. Council on Dental Materials and Equipment. Obstacles to the development of a standard for posterior composite resins. J Am Dent Assoc. 1989; 118: 649-51.
  14. Cook WD. An investigation of radiopacity of composite restorative materials. Aust Dent J. 1981; 26: 105-12.
  15. Watts DC. Characterization of aluminum radiopacity standards for restorative materials. J Dent. 1986; 15: 175-7.
  16. Stanford CM, Fan PL, Schoenfeld CM, Knoeppel R, Stanford JW. Radiopacity of light-cured posterior composite resins. J Am Dent Assoc. 1987; 115: 722-4.
  17. Espelid I, Tveit AB, Erickson RL, Keck SC, Glasspole EA. Radiopacity of restorations and detection of secondary caries. Dent Mater. 1991; 7: 114-7.
  18. Murchinson DF, Cherlton DG, Moore WS. Comparative radiopacity of flowable resin composites. Quintessence Int. 1999; 30: 179-84.
  19. Curtis PM Jr., von Fraunhofer JA, Farman AG. The radiographic density of composite restorative resins. Oral Surg Oral Med Oral Pathol. 1990; 70: 226-30.
  20. Goshima T. Radiographic detection of recurrent lesions associated with composite restorations. Oral Surg Oral Med Oral Pathol. 1990; 70: 236-9.
  21. Bouschlicher MR, Cobb DS, Boyer DB. Radiopacity of compomers, flowable and conventional resin composite for posterior restorations. Oper Dent. 1999; 24: 20-5.
  22. Hara AT, Serra MC, Haiter-Neto F, Rodrigues AL Jr. Radiopacity of esthetic restorative materials compared with human tooth structure. Am J Dent. 2001; 14: 383-6.
  23. Attar N, Tam LE, McComb D. Flow, strength, stiffness and radiopacity of flowable resin composites. J Can Dent Assoc. 2003; 69: 516-21.
  24. Sabbagh J, Vreven J, Leloup G. Radiopacity of resin-based materials measured in film radiographs and storage phosphor plate (Digora). Oper Dent. 2004; 29: 677-84.
  25. International Organization for Standardization. ISO 4049: 2000. Dentistry - polymer-based filling, restorative and luting materials. 3rd ed. Geneva, Switzerland: International Organization for Standardization; 2000.
  26. Scoenfeld CM, Lauterschleger EP, Moore BK, Rechtien JJ. Computerized prediction of optical density for diagnostic radiology. J Dent Res. 1977; 56: 1085-92.
  27. Abreu MJN, Tavares D, Vieira DF. Radiopacity of restorative materials. Oper Dent. 1977; 2: 3-16.
  28. Akerboom HB, Kreulen CM, van Amerongen WE, Mol A. Radiopacity of posterior composite resin, composite resin luting cements, and glass ionomer lining cements. J Prosthet Dent. 1993; 70: 351-5.
  29. Williams JA, Billington RW. The radiopacity of glass ionomer dental materials. J Oral Rehabil. 1990; 17: 245-8.
  30. Jandt KD, Al-Jasser AM, Al-Ateeq K, Volwes RW, Allen GC. Mechanical properties and radiopacity of experimental of glass-silica-metal hybrid composites. Dent Mater. 2002; 18: 429-35.
  31. Goshima T, Goshima Y. Optimum radiopacity of composite inlay materials and cements. Oral Surg Oral Med Oral Pathol. 1991; 72: 257-60.
  32. Tveit AB, Espelid I. Radiographic diagnosis of caries and marginal defects in connection with radiopaque composite fillings. Dent Mater. 1986; 2: 159-62.
  33. Shah PM, Sidhu SK, Chong BS, Ford TR. Radiopacity of resin-modified glass ionomer liners and bases. J Prosthet Dent. 1997; 77: 239-42.
  34. Sidhu SK, Shah PM, Chong BS, Pitt Ford TR. Radiopacity of resin-modified glass ionomer restorative cements. Quintessence Int. 1996; 27: 639-43.

© Copyright 2007 - Piracicaba Dental School - UNICAMP São Paulo - Brazil

 

 


The following images related to this document are available:

Photo images

[os07007t3.jpg] [os07007t2.jpg] [os07007f1.jpg] [os07007t1.jpg]
Home Faq Resources Email Bioline
© Bioline International, 1989 - 2024, Site last up-dated on 01-Sep-2022.
Site created and maintained by the Reference Center on Environmental Information, CRIA, Brazil
System hosted by the Google Cloud Platform, GCP, Brazil