search
for
 About Bioline  All Journals  Testimonials  Membership  News


Brazilian Journal of Oral Sciences
Piracicaba Dental School - UNICAMP
EISSN: 1677-3225
Vol. 6, Num. 22, 2007, pp. 1372-1375

Brazilian Journal of Oral Sciences, Vol. 6, No. 22, 2007, pp. 1372-1375

Thermocycling effect on microhardness of laboratory composite resins

Sarina Maciel Braga Pereira1*, Anderson Almeida Castilho2*, Susana María Salazar-Marocho1*, Karla Mychellyne Costa Oliveira2*, Vanessa Zulema Ccahuana Váquez3*, Marco Antonio Bottino4*

1DDS, MS, Graduate Student
2Research Fellow, Graduate Student
3DDS, MS, PhD
4DDS, MS, PhD, Adjunct Professor
* Department of Dental Materials and Prostheses, Paulista State University, São José dos Campos, UNESP, Brazil.

Correspondence to: Sarina Maciel Braga Pereira Rua Inconfidência 196. Bloco B. Ap 55 São Dimas - CEP12245370 São José dos Campos SP - Brasil Phone: +51-12-8134854 / +51-12-91776292 E-mail:sarambp@yahoo.com.br

Received for publication: May 20, 2007
Accepted: July 30, 2007

Code Number: os07024

Abstract

The aim of this study was to evaluate the thermocycling effect on microhardness of laboratory composite resins. 30 disks were fabricated, 5 mm of diameter and 2mm of width, using 3 laboratory resins: G1 (n=10) - RESILAB MASTER (Wilcos-Brasil), G2 (n=10) - Vita VMLC (VITA Zahnfabrik-Germany), and G3 (n=10) - Vita Zeta (VITA Zahnfabrik-Germany). Vickers microhardness (HV) of all specimens was evaluated using a microhardness tester FM-700 (Future Tech- 50 g/10s). The specimens were measured before and after the thermocycling (3.000 times and 12.000 times - 5° /55°C±1). The microhardness values before cycling were (mean±SD): G1: 55.50±4.6; G2: 35.54±2.5; G3: 27.97±1.6.; after 3.000 thermocycles: G1: 55.54±3,9; G2: 29.92±2,73; G3:21.01±1.4 and after 12.000 cycles G1:54.27±3.2; G2: 30.91±1.6. G3: 23.81±0.9. Variance analysis (ANOVA) and Tukey’s test was accomplished (p<0,05), the highest microhardness values were observed in G1; G2 and G3 showed reduction of microhardness values. It was concluded that, after thermocycling, the tested laboratory composites resins are susceptible to the decrease of surface microhardness.

Key Words: composite resins, microhardness, thermocycling

Introduction

The search for techniques of indirect restorations based on polymers increased due to the evolution of restorative materials and the use of adhesive conservative’s procedures1, just when the ceramic restorations present limitations as abrasiveness, difficult of reparation, brittle and sensitivity in the technique2. These materials provided alternative ways for clinicians to overcome some inherent deficiencies of direct composites restorations, including polymerization shrinkage, inadequate polymerization in deep interproximal areas and restoration of proximal contacts and contour3. In spite of the similar composition, indirect composite restoration is thought to have superior mechanical properties4.

The success of any dental restorative material depends upon its physical, chemical and mechanical properties5-7; thus, second generation composite resins feature several differences in those terms compared to first generation composite resin because it was magnified the flexural strength, wear resistance, elastic modulus, and polymerization shrinkage. However, fracture, abrasion and discoloration of laboratory processed composite resins are significant problems in clinical use8-10. To improve the mechanical properties of laboratory composite resins, inorganic particles are added in its composition which promotes resistance, increases the rigidity, and reduces dimensional changes. When they are warmed and cooled, also reduce the shrinkage, the radiopacity; improve the aesthetic and the manipulation11. The organic matrix influences mechanical properties of some materials10. Also, the organic filler has an effect on the mechanical characteristics of the material; and the reduction of the matrix volume reduces the shrinkage of polymerization and the process of wear4.

It demonstrated that the uptake of water by the matrix was related to a reduction in the mechanical properties of the composite resin12-13. Under oral conditions the temperature changes induced by eating, drinking and breathing. These changes may cause some failures of the composites resins cohesion because of the thermal expansion differences between the matrix and inorganic particles14. Laboratory simulations of clinical service are often performed to analyze dental materials properties, so clinical trials and time consuming are less. Thermocycling is an in vitro process often represented in these simulations; it may vary considerably and, with few exceptions, is always used without reference in vivo observations. Thus, to standard the conditions is necessary to allow comparison among the reports6,15.

Few studies assessed the influence of thermocycling on the microhardness of composite resin. No reports have been found about the necessary number of thermocycles to simulate the use-time of a material in vivo, so it was proposed that 10000 cycles might represent a one year of service16. In front of this, the present study selected two amounts of cycles to be tested, 3000 that is around of what is commonly find on literature and 12000 which is above of that considered to represent one year of use.

The aim of this study was to evaluate the thermocycling influence on the microhardness of indirect composite resins.

Material and Methods

Three laboratory composite resins were selected for the experiment: Resilab Master (Wilcos-Brazil), VITA VM LC and VITA ZETA LC (VITA Zahnfabrik-Germany).

For this study were prepared thirty resin specimens (n=10) which were fabricated using a stainless steel matrix with an internal diameter of 5mm and depth of 3mm.

With a metallic spatula, the laboratory composite resins were condensed into the matrix, in two layers, carrying a initial polymerization for 4 minutes (EDG - LUX-RESILAB MASTER and VITA ZETA LC, Spectramat - VITA VM LC). After the condensation of the second layer, a polyester strap was placed on the resin, to obtain a smooth surface. The final polymerization was made according to manufacturer’s instructions, as follow:

RESILAB MASTER was processed in a light-curing source with wave length between 400 and 500nm and a maximum temperature that not exceed the 50ºC. In this case the equipment of the first layer polymerization, with the maximum thickness of 1,5 mm was carried out, during 4 min and the final polymerization for 12 min (EDG-LUX-Brazil).

VITA VMLC was processed using the light-curing Spectramat (Ivoclar Vivadent/ Liechtenstein), carrying a final polymerization per 10 minutes. For VITA ZETA LC was used a light-curing source with wave length of 400-500 (EDG-LUX-Brazil), carrying a final polymerization for 10 minutes. The specimens were embedded in acrylic resin, and the surfaces were polished using from 220 to 600-grits SiC paper on a roating disc at 150 revolutions/min under water cooling (mechanic polishment) (POLI PAN-2/PANAMBRA, Brazil) with a diamond paste of 6, 3 and 0,25µm. After that, they were stored in distilled water 37°C for 24 hours. The surface of each specimen was evaluated at 0, 3000 and 12000 thermal cycles with baths at 5ºC/55ºC±1 with a dwell time of 30s in each bath by means of Vickers (HV) hardness with a microdurometer FM-700 (Future Tech), with a load of 50 g / 10 seconds. For each surface, three indentations were carried out to obtain the hardness average for each sample. The microhardness data were submitted to statistical analysis, using a two-way ANOVA and Tukey’s test (pd”0.05) it was using the Statistical program Software for Windows (StatSoft, Incorporation, version 5,5, 2000, Tulsa, OK) and Statistix for Windows (Analytical Software, Incorporation, version 8,0, 2003, Tallahase, FL, USA).

Results

The results have shown microhardness average values for each type of laboratory composite resin with or without thermocycling (Table 1). It was verified statistically significant of the resin effect (p=0.001), thermocycling effect (p=0.001) and the interaction (p=0.002) between them (Figure 1). Tukey’s test (5%) showed that there are statistically significant differences among resins. In RESILAB MASTER, the thermocycling (3000 and 1200 cycles) did not produce any alteration on microhardness values; while in VITA VM LC and VITA ZETA LC produced a reduction on microhardness values after 3000 cycles. No statistical difference was showed between 3000 and 12000 cycles in all the groups (Table 1).

Discussion

The hardness can be described as the capacity of a material to resist indentations under constant load or abrasion17. The microhardness is a non destructive laboratorial test, specifically located, that supplies fundamental data about the material18. However, according to Harrison and Draughn19 and Lappalainem et al.20, the microhardness does not have relationship between hardness and wear resistance of composites. Kawai21 has already found the existence of a direct relation between hardness and resistance in resins. Condon22 told that properties of composites are influenced by type, size, load particles volume and degree of linking to resinous matrix. The type of matrix and degree that conversion occurs during the polymerization can also influence mechanical properties. Despite indirect resin materials had presented similar mechanical properties, a time theoretically that its compositions are almost identical, being constituted basically of oxygen, aluminum, silicon and barium, according to Mandikos17.

In this study, all used resins presented ceramic particles in its inorganic matrix. For the three materials, values of microhardness before thermocycling had been superior of 20HV. The RESILAB MASTER and the VITA ZETA LC material micro-hybrid materials, while that VITA VM LC is a microparticle resin.

Microparticle of resins with less percentages of filler particles in its composition, has demonstrated low resistance to fracture, rigidity and fatigue strength, when is comparing to resins with more load23-26. A direct relationship between the particle content and the microhardness can be observed, resins RESILAB MASTER, VITA VM LC, VITA ZETA LC approximately present average percentages of inorganics particles of 53%, 48%, 44%, in weight, respectively. It was observed that VITA ZETA LC had lower microhardness values before being submitted to thermo-cycling, that might had occur due its lower content of inorganic fillers. The materials durability can be affected by the thermocycling14. Water absorption affects the mechanical properties of composites for hydrolytic degradation27. It can also cause microfracture in the interface between fillers and resin matrix, besides induce superficial stress because of high temperature gradient variation close to the surface5,12,28. In our study, we observed a great reduction in the values of microhardness for VITA VM LC and VITA ZETA LC resins with 3000 cycles, while RESILAB MASTER did not show any reduction in these values after any thermocycling effect (Table 1). No statistical difference was showed between 3000 and 12000 cycles in all the groups (Table 1). Thermocycling with 12000 cycles might not have decreased the composite hardness when compared with 3000 cycles, because probably there is a stable level where the composites tested do not suffer alteration for changes in temperature. The main difficult of this study was to determine the number of cycles that the specimens were submitted, because this value is still not established in literature. The effect of thermocycling on others properties laboratorial composites should be investigated. Standard test conditions such as specimen type, dwell times and storage must also be established so that data from different studies can be compared and analyzed. Finally, fracture toughness, surface roughness and flexural strength of these materials should be investigated in future tests. According to the methodology developed in this study it is possible to conclude that G1 presented highest values of microhardness when is compared to G2 and G3. Thermocycling was directly related to the reduction of microhardness values for the G2 and G3, with 3000 cycles; however G1 did not showed statistical difference after thermocycling; and no statistical difference was showed between 3000 and 12000 cycles in all the groups.

Acknowledgements: The authors would like to thank Professor Ivan Balducci for his helpful in the statistical analysis of this study.

References
  1. Touati B, Akdan N. Second generation laboratory composite resins for indirect restorations. J Esthet Dent. 1997, 9: 108-18
  2. Touati B. The evolution of aesthetic restorative materials for inlays and onlays: a review. Pract Periodontics Aesthet Dent. 1996, 8: 657-66.
  3. Roulet JF. Benefits and disadvantages of tooth colored alternatives to amalgam. J Dent. 1997; 25: 459-73.
  4. Cesar PF, Miranda Junior WG, Braga RR. Influence of shade and storage time on flexural strength, flexural modulus, and hardness of composites used for indirect restorations. J Prosthet Dent 2001; 3: 289-96.
  5. Montes-G GM, Draughn RA. In vitro surface degradation of composites by water and thermal cycle. Dent Mater. 1986; 2:193-7.
  6. Crim GA, Mattingly SL. Evaluation of two methods for assessing marginal leakage. J Prosthet Dent. 1981; 45: 160-3.
  7. Craig RG. Materiais dentários restauradores. 11. ed. São Paulo: Santos; 2004
  8. Okada K, Asada M, Omura L, Yamauchi J. A new crown and inlay material “ESTNIA”. J Esthet Dent. 1998; 11: 121.
  9. Sugita T, Nakamura T, Koh T, Nonaka Y, Tanaka K, Mutobe F et al. Physical properties and clinical application of newly highly filler filled materials “Hybrid Ceramics” for posterior prosthesis. J Esthet Dent. 1998; 11: 107.
  10. Anusavice KJ. Phillips science of dental materials. 11. ed. Philadelphia: Saunders; 2003.
  11. Ferracane JL. Current trends in dental composites. Crit Rev Oral Biol Med. 1995; 6: 302-18.
  12. Chadwick RG, McGabe JF, Walls AGW, Storer R. The effect of storage media upon the surface micro hardness and abrasion resistance of three composites. Dent Mater. 1990; 6: 123-8.
  13. Ferracane JL, Berge HX, Condon JR. In vitro aging of dental composites in water – effect of degree conversion, filler volume, and filler-matrix coupling. J Biomed Mat Res. 1998; 42: 465-72.
  14. Kawano F, Ohguri T, Ichikawa T, Matsumoto, N. Influence of thermal cycles in water on flexural strength of laboratoryprocessed composite resin. J Oral Rehabil. 2001; 28: 703-7.
  15. Rossomando KJ, Wendt Sl Jr. Thermocycling and dwell times in microleakage evaluation for bonded restorations. Dent Mater. 1995; 11: 47-51.
  16. Gale MS, Darvell BW. Thermal cycling procedures for laboratory testing of dental restorations. J Dent. 1999; 27: 89-99.
  17. Mandikos MN, McGivney GP, Davis E, Bush, PJ, Carter JM. A comparison of the wear resistance and hardness of indirect composite resins. J Prosthet Dent. 2001; 85: 386-95.
  18. Tantbirojn D, Versluis A, Cheng Y, Douglas WH. Fracture toughness and microhardness of a composite: do they correlate? J Dent. 2003; 31: 89-95.
  19. Harrison A, Draughn RA. Abrasive wear, tensile strengh, and hardness of dental composite resins - is there a relationship? J Prosthet Dent. 1976; 36: 395-8.
  20. Lappalainem R, Yli-Urpo A, Seppa L. Wear of dental restorative and prosthetic materials in vitro. Dent Mater. 1989; 5: 35-7.
  21. Kawai K, Iwami Y, Ebisu S. Effect of resin monomer composition on toothbrush wear resistance. J Oral Rehabil. 1998; 25: 264-8.
  22. Condon JR, Ferracane JL. In vitro wear of composite with varied cure, filler level, and filler treatment. J Dent Res. 1997; 76:1405-11.
  23. Drummond JL. Cyclic fatigue of composite restorative materials. J Oral Rehab 1989; 16: 509-20.
  24. Willems G, Lambrenhes P, Braem M, Celis JP, Vanherle G. A classification of dental composites according to their morphological and mechanical characteristics. Dental Materials. 1992; 8: 310-9.
  25. Braem MLA, Davidson CL, Lambrechts P, Vanherle G. In vitro flexural fatigue limits of dental composites. J Biomed Mat Res. 1994; 28: 1397-402.
  26. Yap AUJ, Teoh SH. Comparison of flexural properties of composite restoratives using the ISO and mini-flexural tests. J Oral Rehabil. 2003, 30: 171-7.
  27. Soderholm KJ, Zigan M, Ragan M, Fischlschweiger W, Bergman M. Hydrolytic degradation of dental composites. J Dent. Res. 1984; 63: 1248-54.
  28. Scarret DC, Ray S. The effect of water on polymer matrix and composite wear. Dent. Mater. 1994; 10: 5-10.

© Copyright 2007 - Piracicaba Dental School - UNICAMP São Paulo - Brazil


The following images related to this document are available:

Photo images

[os07024t1.jpg] [os07024f1.jpg] [os07024f2.jpg]
Home Faq Resources Email Bioline
© Bioline International, 1989 - 2024, Site last up-dated on 01-Sep-2022.
Site created and maintained by the Reference Center on Environmental Information, CRIA, Brazil
System hosted by the Google Cloud Platform, GCP, Brazil