search
for
 About Bioline  All Journals  Testimonials  Membership  News


Brazilian Journal of Oral Sciences
Piracicaba Dental School - UNICAMP
EISSN: 1677-3225
Vol. 9, Num. 2, 2010, pp. 89-93

Braz J Oral Sci, Vol. 9, No. 2, April-June, 2010, pp. 89-93

Original Article

Influence of preparation height and luting agent type on crown retention in molars

1 Specialist in Dental Prosthesis, Postgraduate Program, Dental school, Uningá, Brazil
2 PhD, Dental School, University of Pernambuco; Coordinator of the Postgraduate Program, Dental School, Uningá, Brazil
3 PhD, Dental School, University of Pernambuco; Professor of Scientific Methodology, Postgraduate Program, Dental school, Uningá, Brazil
4 PhD, Professor, Electromechanical Production Engineering Course, Federal Technological University of Paraná, Brazil

Correspondence Address:
Lilian Rigo
Av. Major João Schell, 1121, Vila Santa Terezinha Passo Fundo, RS - CEP 99020-020
Brazil
lilianrigo@via-rs.net


Date of Submission: 27-Oct-2009
Date of Acceptance: 16-Jun-2010

Code Number: os10020

Abstract

Aim: Mechanical characteristics of the preparation along with luting agent are significant elements on the maintenance of fixed prostheses. This study aimed at assessing the retention of metal complete crowns luted with two different luting agents under different preparation height.
Methods: Forty human third molars were selected and prepared to receive total crowns, and were randomly divided in 4 groups: (1) 5-mm preparation height (PH) and RelyX U100 self-adhesive resin cement (SA); (2) 5-mm PH and zinc phosphate (ZP); (3) 3-mm PH and SA; and (4) 3-mm PH and ZP. Crowns were cast in nickel-chromium alloy. The tensile strength was tested in a universal testing machine.
Results: Mean tensile strength values to crown displacement (kgf) and standard deviation were 39.6 (13.0) for group 1; 16.9 (8.1) for group 2; 32.2 (7.9) for group 3; and 10.6 (3.2) for group 4. Overall, the crowns cemented with SA presented significantly higher mean tensile strength values than ZP, and the 5-mm PH presented significantly higher mean tensile strength values than 3-mm PH.
Conclusions: The self-adhesive resin cement and higher preparation height improved crown retention.

Keywords: crown retention, luting agents, preparation design

Introduction

The stabilizing properties of abutments used in cemented complete coverage restorations have been ascribed to retention and resistance form [1],[2],[3]. Geometric configuration of the prepared tooth is essential to promote retention between axial walls of preparation and the prosthetic restoration [4]. The retention shape obtained by tooth preparation must avoid dislocation of the restoration along its insertion axis, acting against tensile forces [5]. Reduction of convergence angle, higher axial surface and minimal occlusal reduction contribute to increase the retentive capability of the prepared tooth [6],[7],[8].

Several types of luting agents are available and the choice for a material depends of various factors. The retention of most luting agents is based on mechanical imbrications in the irregularities of tooth-restoration interface [9],[10]. Zinc phosphate cement is still the most used for crown luting due to its low cost, easy of handling and good mechanical properties [11],[12],[13]. However, it has some negative properties namely solubility in oral environment and absence of adhesive bonding [14].

The resin cements has significant role in increasing crown retention by promoting an adhesive bonding between tooth and restoration, which has increased the use of these luting agents [15]. Nevertheless, the use of these materials requires several steps, mainly for treatment of dental substrate, which make them technically sensitive [16]. Self-adhesive resin cements have been recently introduced on the market. The goal of these luting agents is to combine the easiness of use offered by zinc phosphate cements (they do not demand pretreatment steps) with the favorable mechanical properties, esthetics and adequate adhesion to dental structure of conventional resin cements [17],[18].

The aim of this study was evaluate the influence of preparation height (3- or 5-mm) and type of luting agent (zinc phosphate or self-adhesive resin cement) on the retention of metal complete crowns on molars.

Material and Methods

The study was approved by the Research Ethics Committee of Uninga (Protocol 0089/08). Forty sound human third molars with similar shapes and dimensions, which had been freshly extracted due to orthodontic or periodontal reasons, were used in this study. The selected teeth were scaled, cleaned for debris and stored in saline, which was constantly renewed.

Specimen preparation

The roots were centrally inserted into PVC cylinders (25-mm height x 20-mm internal diameter; Tigre, Joinville, SC, Brazil) containing self-curing acrylic resin (Jet; Classico Artigos Odontologicos Ltda., Sao Paulo, SP, Brazil). The acrylic resin was maintained 2 mm below to the cementoenamel junction [12],[19]. One horizontal perforation was made in the root equidistant from the cementoenamel junction and tooth apex, enabling the passing of a rectangular orthodontic wire (Dental Morelli Ltda., Sorocaba, SP, Brazil) to endure that teeth were not removed from the acrylic resin during the tensile test.

Preparation was standardized by using a mechanical lathe, according to previous studies [20],[21]. Tooth reduction was initiated by positioning the cutting instrument at the cementoenamel junction and then moving it along the axial wall in a cervical-occlusal direction, under constant cooling. Following axial reduction, the external portion of the root was reduced to standardize the cervical area [Figure - 1]. Tapered-shaped preparations had the following characteristics: 6.5-mm upper diameter, 16 degree of convergence and the cervical finish line was in straight-shoulder shape. Finishing was made at 45 degree angle on the edge formed by the axial and occlusal walls, where an approximately 1-mm-wide groove was made all around the preparation using a cylindrical diamond bur (#1090; KG Sorensen, Barueri, SP, Brazil) in a handpiece under water cooling. The diamond bur was used in almost the whole area of preparation, simulating the clinical condition.

The teeth were randomly divided into four groups (n = 10), according to the preparation height and luting agent: Group 1 - tooth prepared with 5 mm of height and crowns fixed using self-adhesive resin cement (RelyX™ U100, lot #318258; 3M ESPE, Seefeld, Germany), according manufacturer′s directions; Group 2 - tooth prepared with 5 mm of height and crowns fixed using zinc phosphate cement (lot #06809007 powder and lot #0040807 liquid, SS White, Sao Paulo, SP, Brazil), according manufacturer′s directions; Group 3 - tooth prepared with 3 mm of height and crowns fixed using self-adhesive resin cement as group 1; and Group 4 - tooth prepared with 3 mm of height and crowns fixed using zinc phosphate cement as group 2.

The preparation heights are presented in [Figure - 2]. Standardization of height was done using a cylindrical diamond bur (#1090; KG Sorensen) in a handpiece under water cooling. The last cut was made in a groove shape, with 0.5 mm depth in the proximal walls along the tooth long axis to guide the insertion pathway of the cast crown. Areas of pulp chamber exposure were closed with a light-cured resin (Z350; 3M ESPE, St. Paul, MN, USA). Specimens were stored in constantly renewed saline until the luting procedure.

Crown cast

Crowns were waxed directly on the prepared teeth [6]. A handle was done on each crown for future joining to the testing machine, using wax wires (Bego, Bremer, Germany) with 1.5 mm of diameter. The wax crowns were invested with proportion of 100 g for 22.5 ml of liquid (Begosol; Bego) and 2.5 mL of water, according to the manufacturer′s directions. The crowns were cast in a NiCr alloy (Wironia; Bego). After divesting, fit was checked, the internal surfaces of the cast crowns were airborne-particle abraded with 110-im aluminum oxide (Korox 110; Bego) under 2 bar of pressure, and cast crowns prepared for luting as presented in [Figure - 3].

Crown luting

The preparation was cleaned using rotary brush and pumice in low-speed hand piece, washed and then dried using sterile cotton [10],[22]. Metallic crown were sandblasted (Microjet; Bio Art Equipamentos Odontologicos Ltda, Sao Carlos, SP, Brazil) with a 50-μm particle stream, cleaned with alcohol and water, and dried with an air stream free of water or oil. Luting procedure was performed according to each manufacturer′s instructions.

The crowns were finger pressed after insertion on the preparation, and were then subjecte dto constant axial pressure of 5 kg for 10 min using a custom-made press that allowed cement flow and correct crown fit on the preparation [12],[19],[23] [Figure - 4]. Excess material was removed with a sharp explorer.

Excesses of RelyX U100 were first light-cured using LED curing unit (Radii Cal; SDI, Australia; 1.200 mW/cm 2 ) for 2 s to facilitate the removal. The margins of the preparation were then light-cured for 30 s at each face. Specimens were stored in distilled water at room temperature for 10 days before of the tensile strength test.

Tensile Strength Test

Crown retention was measured by applying a tensile force to the loop attached to the cast crown in a universal testing machine (EMIC DL 20000, Sao Jose dos Pinhais, PR, Brazil) at a cross-head speed of 0.5 mm/min [13],[24]. Each specimen was positioned on the lower part of the machine. The upper part of the testing machine had a 2.5-mm diameter S-shaped steel hook to which the handles of crowns were connected [Figure - 5]. Tensile force values required to separate the crowns (kgf) was recorded by machine′s software. Lavenes′s test was applied to verify the homogeneity of variances, as well as the Kolmogorov-Smirnov′s test to verify data distribution. As normal distribution was observed, statistical analysis was performed by two-way ANOVA and Tukey′s post-hoc test at 5% significance level. Visual examination of the debonded surfaces of the teeth and crowns was performed.

Results

The results are presented in the [Table - 1]. Both factors, height preparation and luting cement had significant influence on crown retention. Crowns cemented with RelyX U100 (groups 1 and 3) presented significantly higher mean tensile strength values (p<0.0001) than crowns cemented with zinc phosphate cement (groups 2 and 4). The 5-mm preparation height promoted significantly higher mean tensile strength values than 3-mm preparation height (p=0.018). There was no significant interaction between the factors (p=0.847).

Debonded adhesive failure types were predominantly found. For groups 1 and 3, the failures were adhesive between cement and preparation on the axial surfaces; and between cement and crown on the occlusal surface. For groups 2 and 4, on the other hand, the failures were adhesive between cement and crown on the axial surfaces; and between cement and preparation on the occlusal surface.

Discussion

Retention is considered an important requirement in the fixation of prosthetic crowns, and its achievement is dependent on some factors, namely favorable relation between surface geometry of the prepared tooth and the definitive restoration [4],[9],[25],[26],[27],[28]. Clinically, a crown would hardly undergo such great tensile efforts as those applied in this study, but the tested experimental conditions serve as parameters to evaluate different properties and behaviors of the materials used. According to the obtained results, minimum occlusal reduction during preparation contributes significantly to increase the retention [6],[7],[8] , regardless of the type of luting agent used.

The results of the present study may be explained by the fact that higher preparation height promotes greater superficial area with the crown [5],[26],[28],[29]. Although other factors may influence on crown retention, the preparations were standardized (cervical diameter, taper, roughness, piece fit), thus eliminating or minimizing the interference of these variables on the results. Rubo et al. [5] concluded that preparation 2 mm higher contributes significantly for a better retention of crowns. Other studies have shown greater crown retention for preparation with greater height [24],[29],[30],[32].

Concerning of the luting agents, the results showed greater retention [Table - 1] for the RelyX™ U100 self-adhesive resin cement when compared to the zinc phosphate cement, probably due to the adhesive capacity of the resin cement to dentin by hybrid layer formation, improving the retention compared to conventional cements [13],[17],[18]. Moreover, better mechanical properties of resin cement in relation to zinc phosphate cement also influence their tensile, compressive and shearing strengths. The lower tensile strength of the zinc phosphate cement may be related to its ceramic composition, which makes this material friable and less resistant to tensile forces [33]. Zinc phosphate cement does not have chemical adhesion to any dental substrate, acting only as luting agent by mechanical or frictional retention. Thus the height, taper and area of the preparation important aspects for its success as a luting material [32],[34]. Therefore, in situations where preparation retention is deficient, for example, a short clinical crown and accentuated taper of the preparation, the choice for a luting agent lies on resin cement, leading to a more favorable clinical prognosis [15]. However, the difference in tensile strength between the luting agents found in this study does not contraindicates use of the zinc phosphate cement because the retention values obtained were higher that the forces expected clinically, which is around of 4 kgf [23].

Tjan and Li [35] compared the retention of cast crowns luted with adhesive resin cement (Panavia Ex® ) and zinc phosphate cement (Flecks® ), concluding that the resin cement Panavia Ex® provided almost twice the retention values given by zinc phosphate. Browning et al. [12] compared the retentive capacity of three cements (resin, glass ionomer and zinc phosphate) on crown preparations that presented adverse conditions for retention, and found that the resin cement showed significantly higher retention values than the conventional cements. The findings of other studies [13],[36] are in agreement with ours.

Piwowarczyk et al. [16] compared the shear bond strength of luting agents used in fixed prostheses, stating that the self-adhesive resin cement RelyX® Unicem did not differ significantly from other conventional resin cements. However, it presented significantly higher bond strength than glass ionomer, zinc phosphate and resin-modified glass ionomer cements. Martins Pinto [31] verified the tensile strength of metal crowns luted with RelyX™ Unicem, RelyX™ ARC and Hy bond® (zinc phosphate). The author observed higher retention for self-adhesive resin cement RelyX™ Unicem than for the other cements.

Under the tested conditions, it may be concluded that self-adhesive resin cements should be preferred for luting of metal crowns and minimum occlusal reduction should be done on preparation. Further studies using other variables such as thermal cycling, cyclic loading and long-term storage should be performed to confirm the results and hypotheses addressed in the present study.

References

1.Shillingburg HT, Hobo S, Whitsett LD, Jacobi R, Brackett SE. Fundamentals of fixed prosthodontics. 3rd ed. Chicago: Quintessence; 1997. p.139-42, 151-2.  Back to cited text no. 1    
2.Potts RG, Shillingburg HT Jr, Duncanson MG Jr. Retention and resistance of preparations for cast restorations. J Prosthet Dent. 1980; 43: 303-8.  Back to cited text no. 2    
3.Leong EW, Choon Tan KB, Nicholls JI, Chua EK, Wong KM, Neo JC. The effect of preparation height and luting agent on the resistance form of cemented cast crowns under load fatigue. J Prosthet Dent. 2009; 102: 155-64.  Back to cited text no. 3    
4.Satterthwaite JD. Indirect restorations on teeth with reduced crown height. Dent Update. 2006; 33: 210-6.  Back to cited text no. 4    
5.Rubo JH, Amaral MB, Hollweg H, Santos Junior GC, Mendes SNC. Tensile strength of full crowns provided by retention grooves and clinical crown length. Rev Fac Odontol Bauru. 2001; 9: 173-8.  Back to cited text no. 5    
6.Reis AC, Melo Filho AB, I6rio LS, Lima DR, Silva EG. Evaluation of the traction resistance using or not retentions accomplished about prepares to total crowns. Rev Odontol UNESP. 2004; 33: 1-5.  Back to cited text no. 6    
7.Pilo R, Lewinsteina I, Ratzona T, Cardasha HS, Broshb T. The influence of dentin and/or metal surface treatment on the retention of cemented crowns in teeth with an increased taper. Dent Mat. 2008; 24: 1058-64.  Back to cited text no. 7    
8.Ayad MF, Johnston WM, Rosenstiel SF. Influence of tooth preparation taper and cement type on recementation strength of complete metal crowns. J Prosthet Dent. 2009; 102: 354-61.  Back to cited text no. 8    
9.Rosentiel SF, Land MF, Fujimoto J. Pr6tese fixa contemporanea. 31 1 ed. Sao Paulo: Santos; 2002. 868p.  Back to cited text no. 9    
10.Mezzomo E, Suzuki RM. Reabilitagao oral contemporanea. Sao Paulo: Santos; 2006. 873p.  Back to cited text no. 10    
11.Campos TN, Mori M, Henmi AT, Saito T. Marginal microleakage of cast metal crowns luting agents. Rev Fac Odontol Univ Sao Paulo. 1999; 13: 357-62.  Back to cited text no. 11    
12.Browning WD, Nelson SK, Cibirka R, Myers ML. Comparasion of luting cements for minimally retentive crown preparations. Quintessence Int. 2002; 33: 95-100.  Back to cited text no. 12    
13.Consani S, Santos JG, Correr Sobrinho L, Sinhoreti MAC, Sousa-Neto MD. Effect of cement types on the tensile strength of metallic crowns submitted to thermocycling. Braz Dent J. 2003; 14: 193-6.  Back to cited text no. 13    
14.Prates LHM, Consani S, Sinhoreti MAC, Correr Sobrinho L. The influence of luting agents on the retention of dentin-fixed complete cast crowns. Rev Fac Odontol Sao Jose Campos. 2000; 3: 90-7.  Back to cited text no. 14    
15.Prakki A, Carvalho RM. Dual cure resin cements: characteristics and clinical considerations. Rev Fac Odontol Sao Jose Campos. 2001; 4: 22-7.  Back to cited text no. 15    
16.Piwowarczyk A, Lauer HC, Sorensen JA. In vitro shear bond strength of cementing agents to fixed prosthodontic restorative materials. J Prosthet Dent. 2004; 92: 363-76.  Back to cited text no. 16    
17.Piwowarczyk A, Lauer HC. Mechanical properties of luting cements after water storage. Oper Dent. 2003; 28: 535-42.  Back to cited text no. 17    
18.Radovic I, Monticelli F, Goracci C, Vulicevic ZR, Ferrari M. Self-adhesive resin cements: a literature review. J Adhes Dent. 2008; 10: 251-8.  Back to cited text no. 18    
19.Scolaro JM, Valle AL, Bonfante G, Diniz DE. . Cienc Odontol Bras. 2003;6: 12-9.  Back to cited text no. 19    
20.Cara A, Mandetta S. Comparative study of the tensile strength of crows cemented with zinc phosphate with and without previous modified varnish application. Rev Paul Odontol. 1992: 14: 38-40.  Back to cited text no. 20    
21.Sonoki RI, Mori M, Campos TN. Evaluation of cast crowns microleakage and retentive strength after occlusal access for endodontic therapy: in vitro study. Braz Oral Res. 2007; 21(Suppl.1): 284-344.  Back to cited text no. 21    
22.Garbin CA, Silva SBA, Mezzomo E. Cements and cementation. In: Mezzomo E, Suzuki RM. Contemporary oral rehabilitation. Sao Paulo: Santos; 2006. p.791-839.  Back to cited text no. 22    
23.Nakao E, Campos TN, Contin I, Veiga JAL Effect of thermo and mechanical cyclic on retention decrease of cemented cast crows. RPG Rev Pos­Grad. 2006; 13: 157-63.  Back to cited text no. 23    
24.Bresciano M, Schierano G, Manzella C, Screti A, Bignardi C, Preti G. Retention of luting agents on implant abutments of different height and taper. Clin Oral Implants Res. 2005; 16: 594-8.  Back to cited text no. 24    
25.Caputo AA, Stendlee JP. Biomechanics in Clinical Dentistry. Chicago: Quintessence Publishing; 1987. 224p.  Back to cited text no. 25    
26.Mezzomo E. Oral rehabilitation for the clinician. Sao Paulo: Santos; 1994. 561p.  Back to cited text no. 26    
27.Pegoraro LF. Fixed prosthodontics. Sao Paulo: Artes Medicas; 1998. 313p.  Back to cited text no. 27    
28.Saito T. Functional dental preparations in fixed prosthodontics. 21 a ed. Sao Paulo: Santos; 1999. 223p.  Back to cited text no. 28    
29.Bowlwy JF, Kieser J. Axial-wall inclination angle and vertical height interactions in molar full crown preparations. J Dent. 2007; 35: 117-23.  Back to cited text no. 29    
30.Gungor MA, Artung C, Sonugelen M. Parameters affecting retentive force of conus crowns. J Oral Rehabil. 2004; 31: 271-7.  Back to cited text no. 30    
31.Martins Pinto MG. Evaluation of tensile strength of metal crowns in preparation with different heights using three types of cements. [dissertagao]. Canoas: Faculdade de Odontologia, Universidade Luterana do Brasil; 2006.  Back to cited text no. 31    
32.Abbo B, Razzoog ME, Vivas J, Sierraalta M. Resistance to dislodgment of zirconia copings cemented onto titanium abutments of different heights. J Prosthet Dent. 2008; 99: 25-9.  Back to cited text no. 32    
33.Fonseca RG, Santos Cruz CA, AdaboGL, Vaz LG. Comparison of the tensile bond strengths of cast metal crowns luted with resin cements. J Oral Rehabil. 2004; 31: 1080-4.  Back to cited text no. 33    
34.Diaz-Arnold AM, Vargas MA, Haselton DR. Current status of luting agents for fixed prosthodontics. J Prosthet Dent. 1999; 81: 135-41.  Back to cited text no. 34    
35.Tjan AHL, Li T. Seating and retention of complete crowns with a new adhesive resin cement. J Prosthet Dent. 1992; 67: 478-83.  Back to cited text no. 35    
36.Zidan O, Ferguson GC. The retention of complete crowns prepared with three different tapers and luted with four different cements. J Prosthet Dent. 2003; 89: 565-71.  Back to cited text no. 36    

Copyright 2010 - Braz J Oral Sci


The following images related to this document are available:

Photo images

[os10020f3.jpg] [os10020f4.jpg] [os10020f5.jpg] [os10020t1.jpg] [os10020f2.jpg] [os10020f1.jpg]
Home Faq Resources Email Bioline
© Bioline International, 1989 - 2024, Site last up-dated on 01-Sep-2022.
Site created and maintained by the Reference Center on Environmental Information, CRIA, Brazil
System hosted by the Google Cloud Platform, GCP, Brazil