search
for
 About Bioline  All Journals  Testimonials  Membership  News


Brazilian Journal of Oral Sciences
Piracicaba Dental School - UNICAMP
EISSN: 1677-3225
Vol. 9, Num. 3, 2010, pp. 376-379

Braz J Oral Sci, Vol. 9, No. 3, July-September, 2010, pp. 376-379

Porcelain application and simulation of firing cycle: effect on marginal misfit of implant-supported frameworks

Márcia Mika Nakaoka1; Jessica Mie Ferreira Koyama Takahashi2; Juliana Maria Costa Nuñez-Pantoja2; Rafael Leonardo Xediek Consani3; Marcelo Ferraz Mesquita3

1DDS, MS, PhD, Dentistry School, São Lucas College, Porto Velho, RO, Brazil
2DDS, MS, Department of Prosthodontics and Periodontology Piracicaba Dental School State University of Campinas, Piracicaba, SP, Brazil
3DDS, MS, PhD, Department of Prosthodontics and Periodontology Piracicaba Dental School State University of Campinas, Piracicaba, SP, Brazil

Correspondence to: Jessica Mie Ferreira Koyama Takahashi Rua Luíz Razera 300 ap44DR Nova América - 13417-530 Piracicaba, SãoPaulo - Brasil e-mail: jemfkt@yahoo.com.br

Received for publication: April 14, 2010
Accepted: July 06, 2010

Code Number: os10039

Abstract

Aim: Success of implant-supported prostheses is related to the frameworks' passive fit, hence inaccuracies can generate stress, leading to bone resorption and rehabilitation failure. This study evaluated misfit levels of implant-supported frameworks after different coverage treatments.
Methods:
Twenty commercially pure titanium (CP Ti) frameworks were manufactured with 5 Branemark type multi-unit abutments. Frameworks were distributed in two groups as follows: G1 - porcelain application (n=10); G2 - porcelain firing cycle simulation (n=10). Using a traveling microscope, marginal misfit was measured before and after undertaking the techniques, following the single-screw test protocol. All data were submitted to ANOVA and Tukey's test (p<0.05).
Results:
Initial marginal misfit values were not significantly different, but both groups presented significantly higher misfit values after treatment: G1: 233.99 µm (p=0.0003); G2: 119.75 µm (p<0.0001). In addition, G1 presented higher misfit than G2 (p<0.0001).
Conclusions:
Porcelain application promoted significantly higher increase of misfit, which indicates that such procedure should be considered on misfit analysis of implant-supported prostheses.

Keywords: implant-supported prosthesis, prosthesis fitting, esthetic coverage, titanium framework.

Introduction

Over the last 25 years, implant prostheses have become a frequent and reliable rehabilitation option for partially and completely edentulous patients1-6. After Branemark first started studying osseointegrated implants and the use of gold alloy frameworks in the early seventies5,7, several studies have described the possibility of using other materials, such as cobalt-chromium alloy8,silver-palladium alloys9 and titanium5.

Titanium presents great biocompatibility and corrosion resistance even in challenging environments such as the oral cavity, and was thus the first choice to fabricate dental implants. The success of titanium implants led to applying titanium for other purposes, such as manufacturing prosthetic frameworks10-11.

Even though the bone-implant interface is extremely reliable, there are still some technical difficulties regarding the manufacturing process, which include the inability to make frameworks with intimate adaptation and to correct prosthesis misfit2,9,12. Frameworks without passive fit can generate stress between the framework, prosthetic components and bone13. It can cause fracture of the prosthetic components, screw loosening and even induce bone resorption, leading to failure of the osseointegration14-15. Framework misfit occurs more frequently on multiple-element implant-supported prostheses2,4-5,16.

Framework distortion can originate from waxing and inclusion processes17, one-piece casting18 and irregularities in margins and UCLA abutment screws19-20. Porcelain application can also increase distortion in implant-supported frameworks21, depending on alloy type, porcelain contraction, thermal coefficients of the porcelain and alloy, and even framework design17.

Since veneer application can promote distortion and misfit of implant-supported frameworks, the purpose of this study was to compare the effects of porcelain application and simulation of porcelain firing cycle on misfit of implant-supported Ti frameworks.

Material and methods

Material specification, commercial brands and composition of the titanium alloy and porcelain employed in the present study are shown in Table 1.

A metal matrix containing 5 Branemark type implants (4.1 platform) with multi-unit abutments (Conexão Sistema de Próteses, Arujá, SP, Brazil) was molded using square transfers united with acrylic resin (Pattern; GC America, Alsip, IL, USA) and polyether (Impregum Soft; 3M ESPE AG, ESPE Platz, Seefeld, Germany). A casting mold was made containing the analogs, over which a ten element-fixed prosthesis framework with 10 mm cantilever was waxed using calcinable multi-unit copings (Conexão Sistema de Próteses). The waxed framework was duplicated using industrial silicone22 to standardize frameworks (n=20). The silicone molds were then filled with plasticized wax, thereby producing identical specimens for casting, which was performed on a Rematitan machine (Dentaurum; Dentaurum J. P. Winkelstroeter KG, Pforzheim, Germany) using Tritan alloy.

A gypsum index was made for each framework to discharge from the measurements the misfit caused by the casting process. Since each framework was adjusted to its index, only the gap originated by the veneering techniques was measured. After the index was formed, initial misfit was measured.

A traveling microscope (Micro Vision; Leika, Wetzlar, Germany) with ×120 zoom and 0.05 µm precision was used to measure vertical linear dimensional alterations. Frameworks were positioned on the gypsum index and the single screw test protocol was followed. Screw from implant A was fixed with a torque control device (Conexão Sistemas de Prótese) using a 10 Ncm tightening force. This procedure allowed for checking the adaptation of the components on implants C and E. The protocol was repeated by tightening the screw of distal implant E and measuring the gap on implants C and A13,17,21. Measurements were taken three times on each implant (A, C and E) on buccal and lingual on diametric opposed sides.

Specimens were then distributed into groups for either porcelain application (G1) or simulation of the porcelain firing cycle (G2). G1 specimens were sandblasted with aluminum oxide spray with particles of 150 µm and 2.064 kgf/cm2 pressure. Porcelain (Triceram; Dentaurum J. P. Winkelstroeter KG, Pforzheim, Germany) was applied using a silicone wall (Zetalabor; Zhermack, Rovigo, Italy) to standardize all prostheses. Firing cycles were the same for both groups and were performed as described by the porcelain's manufacturer, with G2 specimens being placed alongside G1 specimens for firing.

Marginal misfit was observed after porcelain application and simulation of the firing cycles following the single-screw test protocol (Figure 1). All data were analyzed statistically by repeated-measures ANOVA and Tukey's test (p<0.05).

Results

Table 2 presents the mean marginal misfit values in µm (and standard deviations) of both groups, before and after treatment.

The porcelain group (G1) initially presented a mean misfit of 44.75 µm ± 13.73, and the group with simulated firing cycle (G2) presented mean misfit of 38.57 µm ± 16.94, and these values did not differ statistically from each other (p=1.000).

After treatment, both groups presented statistically significant higher marginal misfit values than initial ones: G1-233.99 µm ± 39.18 (p=0.0003) and G2-119.75 µm ± 38.08 (p<0.0001). Comparing the groups after treatments, porcelain application group presented higher misfit values than the firing cycle simulation group (p<0.0001).

Discussion

Distortions in metal frameworks can compromise prosthesis adaptation. In the case of implant-supported prostheses, distortion can cause stress on the implant bone interface resulting in bone resorption and failure of the rehabilitation. In more severe cases, distortion can even cause failure of the implants.

Framework misfit of the implant platform might originate from several factors, one of which being porcelain application21. Several studies9,23 have demonstrated that simulation of porcelain firing cycle can also increase misfit in implant-supported frameworks.

Initial misfit was measured considering that, even when polished, there is not a complete juxtaposition of the implant and framework surfaces, leaving a gap between the two. Initial misfit values were not statistically different between the two groups, which indicated a similarity between the frameworks after casting, allowing the comparison of the treatments effect to be made.

Both groups presented higher misfit values after treatment. Statistical analysis showed that this increase was significant for porcelain application (44.75 µm ± 13.73 to 233.99 µm ± 39.18; p=0.0003) as well as for porcelain firing cycle simulation (38.57 µm ± 16.94 to 119.75 µm ± 38.08; p<0.0001).

Frameworks that received porcelain application presented a greater increase in marginal misfit values than the ones submitted only to firing cycle simulation (p<0.0001). This fact can be related to contamination of the framework's inner surface during application of the esthetic covering24. Since small amounts of porcelain tend to be translucent, their visualization is very difficult, making removal even harder. Residual porcelain could cause irregularities on the surface in contact with the implant and compromise implant adaptation.

Different contraction coefficients of the porcelain and the metal may also be responsible for deformation after application and firing. Furthermore, porcelain rigidity can compromise metal resilience25, which could increase framework misfit.

Even though firing cycle simulation submits the metal framework to the effects of high temperature, some differences are encountered when porcelain is actually applied and not just simulated. These differences might be due to interactions between the materials. Buchanan et al.25 observed that most framework misfit occurs after oxidation and glazing, due to the higher firing temperatures and cooling procedure of these steps. The slow cooling rate of frameworks during oven/vacuum processing favors the oxidation phase26, which can increase metallic distortions.

Framework distortion after firing may be due to the high temperatures involved in the firing process or it may be due to alloy contamination during the casting process.

Contamination may reduce the melting point of the alloy and promote grain growth27. Such phenomenon might explain the distortions presented by the simulation group.

In the present study, even the smallest deformation caused by porcelain application and firing cycles could present a significant increase in misfit due to the long extension of the frameworks, simulating a 10-element fixed implant-supported prosthesis.

It can be suggested that both porcelain application and firing cycle play important roles on framework misfit, since the final prosthesis results from the association of metal with an esthetic cover. Consequently, this association should be considered when studying the fit of alterations.

In conclusion, the present study demonstrated that simulation of the porcelain firing cycle does not replace porcelain application in analyses of prosthesis misfit. Since final misfit of the prosthesis is obtained after esthetic coverage, any modifications to the metal framework, such as porcelain application, would influence their final misfit. Due to different mechanical properties of the materials and possible contamination during the casting process, any changes in prosthesis fit might be considered to result from the association of porcelain application and firing cycle.

Acknowledgements

This research was supported by FAPESP (grant 2004/13629-5).

References

  1. Aparicio C. A new method to routinely achieve passive fit of ceramometal prostheses over Branemark osseointegrated implants: a two-year report. Int J Periodontics Restorative Dent. 1994; 14: 404-19.
  2. Carlson B, Carlsson GE. Prosthodontic complications in osseointegrated dental implant treatment. Int J Oral Maxillofac Implants. 1994; 9: 90-4.
  3. Jemt T. Fixed implant-supported prostheses in the edentulous maxilla. A five-year follow-up report. Clin Oral Implants Res. 1994; 5: 142-7.
  4. Jemt T, Book K. Prosthesis misfit and marginal bone loss in edentulous implant patients. Int J Oral Maxillofac Implants. 1996; 11: 620-5.
  5. Jemt T, Back T, Petersson A. Precision of CNC-milled titanium frameworks for implant treatment in the edentulous jaw. Int J Prosthodont. 1999; 12: 209-15.
  6. Jemt T, Bergendal B, Arvidson K, Bergendal T, Karlsson LD, Linden B et al. Implant-supported welded titanium frameworks in the edentulous maxilla: a 5-year prospective multicenter study. Int J Prosthodont. 2002; 15: 544-8.
  7. Branemark PI, Hansson BO, Adell R, Breine U, Lindstrom J, Hallen O et al. Osseointegrated implants in the treatment of the edentulous jaw. Experience from a 10-year period. Scand J Plast Reconstr Surg Suppl. 1977; 16: 1-132.
  8. Hulterstrom M, Nilsson U. Cobalt-chromium as a framework material in implant-supported fixed prostheses: a preliminary report. Int J Oral Maxillofac Implants. 1991; 6: 475-80.
  9. Zervas PJ, Papazoglou E, Beck FM, Carr AB. Distortion of three-unit implant frameworks during casting, soldering, and simulated porcelain firings. J Prosthodont. 1999; 8: 171-9.
  10. Parr GR, Gardner LK, Toth RW. Titanium: the mystery metal of implant dentistry. Dental materials aspects. J Prosthet Dent. 1985; 54: 410-4.
  11. Lautenschlager EP, Monaghan P. Titanium and titanium alloys as dental materials. Int Dent J. 1993; 43: 245-53.
  12. Kan JY, Rungcharassaeng K, Bohsali K, Goodacre CJ, Lang BR. Clinical methods for evaluating implant framework fit. J Prosthet Dent. 1999; 81: 7-13.
  13. Jemt T. Failures and complications in 391 consecutively inserted fixed prostheses supported by Branemark implants in edentulous jaws: a study of treatment from the time of prosthesis placement to the first annual checkup. Int J Oral Maxillofac Implants. 1991; 6: 270-6.
  14. Jemt T, Lekholm U. Oral implant treatment in posterior partially edentulous jaws: a 5-year follow-up report. Int J Oral Maxillofac Implants. 1993; 8: 635-40.
  15. Sahin S, Cehreli MC. The significance of passive framework fit in implant prosthodontics: current status. Implant Dent. 2001; 10: 85-92.
  16. Jemt T. Three-dimensional distortion of gold alloy castings and welded titanium frameworks. Measurements of the precision of fit between completed implant prostheses and the master casts in routine edentulous situations. J Oral Rehabil. 1995; 22: 557-64.
  17. Romero GG, Engelmeier R, Powers JM, Canterbury AA. Accuracy of three corrective techniques for implant bar fabrication. J Prosthet Dent. 2000; 84: 602-7.
  18. Schiffleger BE, Ziebert GJ, Dhuru VB, Brantley WA, Sigaroudi K. Comparison of accuracy of multiunit one-piece castings. J Prosthet Dent. 1985; 54: 770-6.
  19. Schmitt SM, Chance DA, Cronin RJ. Refining cast implant-retained restorations by electrical discharge machining. J Prosthet Dent. 1995; 73: 280-3.
  20. Evans DB. Correcting the fit of implant-retained restorations by electric discharge machining. J Prosthet Dent. 1997; 77: 212-5.
  21. Byrne D, Houston F, Cleary R, Claffey N. The fit of cast and premachined implant abutments. J Prosthet Dent. 1998; 80: 184-92.
  22. Bridger DV, Nicholls JI. Distortion of ceramometal fixed partial dentures during the firing cycle. J Prosthet Dent. 1981; 45: 507-14.
  23. Papazoglou E, Brantley WA, Johnston WM. Evaluation of high-temperature distortion of high-palladium metal-ceramic crowns. J Prosthet Dent. 2001; 85: 133-40.
  24. 24. Faucher RR, Nicholls JI. Distortion related to margin design in porcelain-fused-to-metal restorations. J Prosthet Dent. 1980; 43: 149-55.
  25. Buchanan WT, Svare CW, Turner KA. The effect of repeated firings and strength on marginal distortion in two ceramometal systems. J Prosthet Dent. 1981; 45: 502-6.
  26. Monday JJ, Asgar K. Tensile strength comparison of presoldered and postsoldered joints. J Prosthet Dent. 1986; 55: 23-7.
  27. Fonseca JC, Henriques GE, Sobrinho LC, de Goes MF. Stress-relieving and porcelain firing cycle influence on marginal fit of commercially pure titanium and titanium-aluminum-vanadium copings. Dent Mater. 2003; 19: 686-91.

Copyright 2010 - Braz J Oral Sci


The following images related to this document are available:

Photo images

[os10039f1.jpg] [os10039t2.jpg] [os10039t1.jpg]
Home Faq Resources Email Bioline
© Bioline International, 1989 - 2024, Site last up-dated on 01-Sep-2022.
Site created and maintained by the Reference Center on Environmental Information, CRIA, Brazil
System hosted by the Google Cloud Platform, GCP, Brazil