search
for
 About Bioline  All Journals  Testimonials  Membership  News


Brazilian Journal of Oral Sciences
Piracicaba Dental School - UNICAMP
EISSN: 1677-3225
Vol. 10, Num. 2, 2011, pp. 105-108

Brazilian Journal of Oral Sciences, Vol. 10, No. 2, Apr-Jun, 2011, pp. 105-108

Effect of finishing and polishing techniques on the surface roughness of a nanoparticle composite resin

Vera Lucia Schmitt1, Regina Maria Puppin-Rontani2, Fabiana Scarparo Naufel1, Danielle Ludwig3, Julio Katuhide Ueda1, Lorenço Correr Sobrinho2

1DDS, MSc, PhD, Department of Restorative Dentistry, Paraná West State University, Brazil
2DDS, MSc, PhD, Department of Restorative Dentistry, Dental Materials Division, Piracicaba Dental School, State University of Campinas, Brazil
3Undergraduate student, Paraná West State University, Brazil

Received for publication: October 04, 2010 Accepted: May 09, 2011

Code Number: os11021

Abstract

Aim: To evaluate the surface roughness of the resin Filtek Z350 (3M ESPE) after different finishing and polishing techniques.
Methods:
Sixty specimens of 7x2 mm were made and distributed in 6 groups (n=10), according to the technique employed: G1 (control) - polyester strip - no finishing or polishing; G2- multi-blade burs; G3- diamond burs 3195F and 3195FF; G4- Diamond Pro Discs (FGM); G5- Sof-Lex Discs (3M ESPE); G6- Robinson bristle brushes with pumice paste for 20 s and felt disc with 2-4 µm diamond paste for 30 s. The specimens were stored in artificial saliva at 37°C for 7 days. After the finishing and polishing techniques, surface roughness (Ra, µm) was measured using Surf-Corder profilometer SE 1700. Data were subjected to one-way ANOVA and Tukey's test at 5% significance level.
Results:
G3 presented the highest surface roughness mean value (0.61). G5 presented the lowest surface roughness mean value (0.15), but it was not significantly different from G1, G4 and G6.
Conclusions:
According to the obtained results, Z350 composite resin presented the lowest surface roughness when finishing and polishing systems were used (Sof-lex and Diamond Pro discs and Robinson bristle brush with pumice plus Diamond® felt disc with Diamond Excel® paste). The use of diamond burs (G3) resulted in the highest composite surface roughness. There was no significantly different between G1, G4, G5 and G6.

Keywords: dental polishing, composite resin, nanotechnology.

Introduction

Due to their broad use in dentistry since their introduction, light-activated composite resins have been constantly improved. One of the most significant improvements regarding is related to the used of nanotechnology. The new composites, have advantages such as lower polymerization shrinkage, improved mechanical properties, favored optical behavior, better brightness, extended maintenance of surface smoothness, better color stability and lower wear1-3. Filtek Z350 composite resin (3M ESPE), one of those nanoparticle composites, presents zirconia and silica particles4, with approximate size between 5-20 nm and pre-polymerized nanoclusters ranging from 0.6 to 1.4 micrometers5.

The organic matrix structure and the characteristics of fillers exert a direct influence on the surface roughness and staining susceptibility of composite resins. Besides the effect of composition and conversion degree,finishing and polishing procedures can also influence the surface quality of composite resins and are related toroughness and staining6-7.

Clinical procedures including finishing and polishing of composite resins improve esthetic results and restoration longevity. Rough surfaces predispose restorations to increase of bacterial biofilm accumulation, facilitating the development of secondary caries8, discoloration and staining9, and compromise final brightness and esthetics9-10. Greater surface roughness also increases the absorption of chemical components from beverages and foods, which, once retained within the previously formed bacterial biofilm, diffuse into the composite possibly affecting the formed polymer, inducing degradation11.

Finishing and polishing procedures require sequential use of instruments with gradual decrease in particles abrasiveness, aiming to obtaining a brighter and smoother surface12. There is no consensus in the literature regarding the effectiveness of the different systems used for finishing and polishing of composite resins. While some reports state that the use of multi-blade burs prior to abrasive discs or rubbers is a key step to achieve adequate surface smoothness13, others advocate the effectiveness of one-step polishing systems14-16. Moreover, Heintze et al.17 observed a considerable decrease on the mean surface roughness after 20 s of polishing of practically every restorative materials tested in their study and stated that increasing the polishing time did not result in significant improvements on surface smoothness17. The aim of this study was to evaluate the surface roughness of the nanocomposite resin Filtek Z350(3M ESPE) after different finishing and polishing techniques.The tested hypothesis was that different finishing and polishing techniques provide different surface roughness onthe resin.

Material and methods

Sixty specimens of Filtek Z350 composite resin (3M/ESPE) were used (n=10). The characteristics of Filtek Z350are described on Table 1.

The procedures were performed in a special room according to the American Dental Association specification #27 for direct composite resin restorations. Those specifications are related only to the temperature and humidity conditions to insert the composite resin into the matrix18.

A metallic matrix (2 mm high and 7 mm diameter) was used to fabricate the specimens. Composite resin was inserted into the matrix, covered with clear polyester matrix strips, pressed with glass slides and light activated following themanufacturer's instructions using a halogen light device(Optilux 501, Kerr Corp., Orange, CA, USA). The curing tip was positioned perpendicular to specimen surface and a poweroutput density of 620 mW/cm2 was used, as frequently monitored with a curing radiometer.

The specimens were stored at 37ºC and 100% relativehumidity for 7 days prior to finishing and polishing procedures. Finishing and polishing systems and theirrespective compositions are described in Table 2. The specimens were divided into 6 groups (n= 10) according to the finishing and polishing systems as described on Table 3.

The roughness (Ra, µm) readings were carried out usinga profilometer (Kosaka Lab. SE 1700) with 0.25 mm cutoffand 0.1 mm/s speed. Three consecutive measurements in different areas on the polished surface were made and anaverage number was calculated. The specimens were polished by a single operator in order to reduce technique variability and surface roughness was measured again immediately after polishing.

Data were analyzed by one-way ANOVA and Tukey's test for individual comparisons between groups. The significance level was set at 5%.

Results

The mean values, standard deviation and statistical comparisons for surface roughness (µm) are shown on Figure 1.

A one-way ANOVA test indicated significant effects ofthe finishing/polishing techniques. The use of fine and ultrafine diamond burs (G3) resulted in the roughest surfaces, followed by multi-blade burs (G2), although there was no statistically significant difference between them (p>0.05).Robison bristle brush with pumice plus felt disc with diamond paste (G6) did not differ significantly from Control (G1),Diamond Pro discs (G4), Sof-Lex discs (G5) and multi-bladeburs (G2). G1, G4 and G5 presented the smoothest surfaces and differed significantly (p<0.05) from G2 and G3.

Discussion

The surface roughness of composite resin is dependenton the microstructure created by the sequence of physical procedures used to modify this surface. In this study the tested hypothesis was partially accepted. Different finishing  and polishing techniques provided different surface roughness values.

The use of clear polyester strips over the last incrementof material in composite resin restorations is a usual step toavoid the oxygen inhibition layer on the resin surface. However, the resulting surface is rich in organic matrix brought about from the material, leading to a relatively unstable surface. The use of finishing and polishing techniques is essential to favor the chemical stability and improve the mechanical properties of the composite resin surface13. However, these procedures can increase surface roughness at different degrees, depending on the polishing system and material used. In the present study, the smoothest surface was obtained using Diamond Pro (G4), sequential Sof-Lex system discs (G5), and Robison bristle brush with pumice plus felt disc with diamond paste (G6), but they did not differ from the surfaces obtained with use of clear polyester strips (G1 - control group). These results corroborate those of Yap et al. 200419.

The geometric structure of the filler particles content of Filtek Z350 3M ESPE might be a possible explanation for these results. Furthermore, the micromorphology of composite resin surfaces after finishing and polishing is strongly influenced by the amount, geometry and size of fillers. As the tested material is a nanoparticle composite resin, the fillers are round, smaller and more homogeneously distributed,leading to less wear (which will also be more homogeneousif it occurs)13. Composite resins with smaller fillers provide protection to the resin matrix and consequently a better clinical performance with less wear and improved polishing11. Özgünaltay et al. (2003)20 stated that Sof-Lex discs provide smoother surfaces and can be indicated when necessary. Other discs may also provide good polishing results. The DiamondPro (FGM) sequential discs (G4) provided adequate polishing,

Effect of finishing and polishing techniques on the surface roughness of a nanoparticle composite resin being similar to Sof-Lex system discs (G5), and similar resultswere found in this study.

Group 3 (diamond polishing burs) provided the highest roughness, differing significantly different from the other groups, except for G2 (multi-blade burs). This is possibly because the diamond bur is highly wear resistant6, but it makes difficult surface leveling for the final polishing.  Therefore, these bur should be only used for polishing incases where extensive removal of composite resin is required1.

The combination of polishing pastes after the use ofabrasives (G6) did not show different mean surface roughness values from the the Diamond Pro (G4) sequential discs aloneor the Sof-Lex polishing system (G5). Polishing systems like Diamond Pro (G4) have smaller abrasive particles and, theoretically, they should have promoted the best composite polishing in association with felt discs, providing smooth and bright surfaces. However, this fact was not observed in the present study. According to Costa et al. (2007)21, it could be explained by the quality of abrasive used in each system. Differences in composition and the physical properties, such hardness, are expected to influence the surface polishing more than the dimensions of abrasive particles6.

Bollen et al. (1997)22 stated that surface roughness greater than 0.2 µm (Ra) may lead to bacterial colonization onto the restoration and increase the risk of secondary caries. Ra values lower than 0.2 µm were obtained in the present study for Filtek Z350 3M ESPE composite resin in the control, Sof-Lex, Diamond Pro sequential discs and Robinson bristle brush/pumice + diamond paste/felt disc groups.

According to the obtained results, Filtek Z350 composite resin presented the smoothest surface when no finishing and polishing was done and when these procedures were performed with Sof-lex and Diamond Pro Al2O3 flexible discs and Robinson bristle brush with pumice followed by Diamond® felt disc with Diamond Excel® diamond polishingpaste. Multi-blade and diamond polishing burs (bur/point)did not promote an adequate surface smoothness.

References
  1. Jung M, Eichelberger K, Klimek J. Surface geometry of four nanofiller and one hybrid composite after One-step and multiple-step Polishing. Oper Dent. 2007; 32: 347-55.
  2. Marghalani HY. Effect of finishing/polishing systems on the surface roughness of novel posterior composites. J Esthet Restor Dent. 2010; 22: 127-38.
  3. Mitra SB, Wu D, Holmes BN. An application of nanotechnology in advanced dental materials. J Am Dent Assoc. 2003; 134: 1382-90.
  4. Anusavice JK. Phillips Science of dental materials. 11th ed. Saint Louis: Saunders; 2003.
  5. 3M Dental Products Filtek Supreme Plus Universal Restorative system. Saint Paul: Technical product Profile; 2005.
  6. Jefferies SR. Abrasive finishing and polishing in restorative dentistry: a state-of-the-art review. Dent Clin North Am. 2007; 51: 379-97.
  7. Venturini D, Cenci MS, Demarco FF, Camacho GB, Powers JM. Effect of polishing techniques and time on surface roughness, hardness and microleakage of resin composite restorations. Oper Dent. 2006; 31: 11-7.
  8. Uno S, Asmussen E. Marginal adaptation of restorative resin polymerized at reduced rate. Scand J Dent Res. 1991; 99: 440-4.
  9. Yap AUJ, Tan KB, Bhole S. Comparison of aesthetic properties of toothcolores restorative materials. Oper Dent. 1997; 22: 167-72.
  10. Hoelscher DC, Neme AM, Pink FE, Hughes PJ. The effect of three finishing systems on four esthetic restorative materials. Oper Dent. 1998; 23: 36-42.
  11. Ferracane JL. Elution of leachable components from composites. J Oral Rehabil. 1994; 21: 441-52.
  12. Jones CS, Billington RW, Pearson GJ. The in vivo perception of roughness of restorations. Brit Dent J. 2004; 196: 42-5
  13. Turssi CP, Ferracane JL, Serra MC. Abrasive wear of resin composites as related to finishing and polishing procedures. Dent Mat. 2005; 21: 641-8
  14. Ergücü Z, Turkün LS, Aladag A. Color stability of nanocomposites polished with one-step systems. Oper Dent. 2008; 33: 413-20.
  15. Ergücü Z, Turkün LS. Surface roughness of novel resin composites polished with one-step systems. Oper Dent. 2007; 32:185-92.
  16. Korkmaz Y, Ozel E, Attar N, Aksoy G. The influence of one-step polishing systems on the surface roughness and microhardness of nanocomposites. Oper Dent. 2008; 33: 44-50
  17. Heintze SD, Forjanic M, Rousson V. Surface roughness and gloss of dental materials as a function of force and polishing time in vitro. Dent Mater. 2006; 22: 146-65.
  18. Nihei T, Kurata S, Kondo Y, Umemoto K, Yoshino N, Teranaka T. Enhanced hydrolytic stability of dental composites by use of fluoroalkyltrimethoxysilanes. J Dent Res. 2002; 81: 482-6.
  19. Yap AUJ, Yap SH, Teo CK, Ng JJ. Comparison of surface finish of new aesthetic restorative materials. Oper Dent. 2004; 29: 100-4.
  20. Özgünaltay G, Yazici AR, Görücü J. Effect of finishing and polishing procedures on the surface roughness of new tooth coloured restoratives. J. Oral Rehabil. 2003; 30: 218-24.
  21. da Costa J, Ferracane J, Paravina RD, Mazur RF, Roeder L. The effect of different polishing systems on surface roughness and gloss of various resin composites. J Esthet Restor Dent. 2007; 19: 214-24.
  22. Bollen CML, Lambretchts P, Quirynen M. Comparison of surface roughness of oral hard material to the threshold surface roughness for bacterial plaque retention: a review of the literature. Dent Mater. 1997; 13: 258-69.

Copyright © 2011 - Brazilian Journal of Oral Sciences


The following images related to this document are available:

Photo images

[os11021t3.jpg] [os11021f1.jpg] [os11021t1.jpg] [os11021t2.jpg]
Home Faq Resources Email Bioline
© Bioline International, 1989 - 2024, Site last up-dated on 01-Sep-2022.
Site created and maintained by the Reference Center on Environmental Information, CRIA, Brazil
System hosted by the Google Cloud Platform, GCP, Brazil